Uploaded by evg0708

FANUC 32 Model-B Commissioning

advertisement
Register
1
0
Commissioning
Fanuc 32 i Model-B
FANUC
Version 1.1
Version: 09.01.2014
EMAG ES
Service Manual
04.04.14
FANUC
1/49
Register
1
0
1
Register
1
Register ................................................................................................. 2
1
General reference ................................................................................. 4
1.1
Hardware for commissioning .................................................................. 4
1.2
Software for commissioning ................................................................... 4
1.3
Touch panel EMAG 12" ......................................................................... 5
1.4
Description oft he virtual keypad ............................................................ 6
1.5
Description of push buttons .................................................................... 7
2
General settings ................................................................................... 8
2.1
Remove write protection for parameters ................................................ 8
3
Activate USB- front .............................................................................. 9
3.1
Set parameter 20 I/O CHANNEL to 4 .................................................... 9
3.2
Set parameter 300#0 PCM to 1 ........................................................... 10
4
Import of data using the USB port .................................................... 11
4.1
Import of the following data .................................................................. 11
4.2
Start the controller by using the boot menu ......................................... 11
4.3
Check the setting of the USB – front interface ..................................... 12
4.4
Changing the setting of the USB – front interface ................................ 13
4.5
Import of files ........................................................................................ 14
5
Import of data with USB interface .................................................... 16
5.1
The following data will be imported ...................................................... 16
6
Import parameter ................................................................................ 17
6.1
Import the CNC-PARA.TXT file ............................................................ 17
7
Password safety ................................................................................. 20
7.1
Set the password for safety CNC- parameter ...................................... 20
7.2
Delete PMC parameters ....................................................................... 22
8
Start the conroller with boot menu ................................................... 23
EMAG ES
Service Manual
04.04.14
FANUC
2/49
Register
1
0
8.1
Clear PMC parameter file ..................................................................... 23
8.2
Import of PMC parameters ................................................................... 26
8.3
Import PMC1_PRM.TXT ...................................................................... 26
8.4
Import of PMCS_PRM.TXT .................................................................. 30
8.5
Switch machine OFF / ON.................................................................... 30
9
Setting of watch and date ................................................................. 31
10
Import of NC- programs ..................................................................... 32
10.1
Import NC-programs Cannel 1 ............................................................. 32
10.2
Import files ............................................................................................ 34
10.3
Import NC-programs Cannel 2 ............................................................. 36
10.4
Import NC-Programs LIBRARY ............................................................ 37
11
Check NC-Programs .......................................................................... 41
11.1
Check NC-Programs Cannel 1 ............................................................. 41
11.2
Check NC-Programs Cannel 2 ............................................................. 41
11.3
Check NC-Programs LIBRARY ............................................................ 42
11.4
Check NC-Programs register in primitive state .................................... 42
12
Commissioning of the axis................................................................ 43
12.1
Commissioning of the axis ................................................................... 43
13
Pro bus system................................................................................... 45
14
Parameter check sum fault ............................................................... 47
15
Spezification according to work order and machine type ............. 49
EMAG ES
Service Manual
04.04.14
FANUC
3/49
1
General reference
1
Hardware for commissioning
1.1
General reference
1.1
Hardware for commissioning
• USB-Stick
• PCMCIA-card with adapter
1.2
Software for commissioning
To be imported from network drive:
T:\ELEKTRIK_SOFTWARE\FANUC\Saeulenmaschine\VLx\Version_V_X_X
It is mandatory to always use the newest version number.
Important:
Only use software versions that are released by the engineering department.
EMAG ES
Service Manual
04.04.14
FANUC
4/49
1.3
General reference
1
Touch panel EMAG 12"
1.3
Touch panel EMAG 12"
1
8
2
3
6
4
7
5
1. Touch panel 12“
2. Emergency stop
3. Machine Off
4. Machine On
5. Setting switch
6. Door
7. Options
8. USB-front interface
EMAG ES
Service Manual
04.04.14
FANUC
5/49
1.4
General reference
1
Description of the virtual keypad
1.4
Description of the virtual keypad
The virtual keypad can be selected on / off by pushing the button ABC at the
touch panel.
EMAG ES
Service Manual
04.04.14
FANUC
6/49
1.5
General reference
1
Description of push buttons
1.5
Description of push buttons
• All grey highlighted markings refer to the operator panel EMAG 12“
• All yellow highlighted markings refer to the menu items on the screen as
well as to the virtual keypad.
• All pink highlighted markings refer to the input fields.
EMAG ES
Service Manual
04.04.14
FANUC
7/49
2
2.1
General settings
2
Remove write protection for parameters
2.1
General settings
Remove write protection for parameters
SET/OFS >
EMAG ES
> SETTING > (OPRT) > ON:1
Service Manual
04.04.14
FANUC
8/49
3
3.1
Activate USB- front
3
Set parameter 20 I/O CHANNEL to 4
3.1
Activate USB- front
Set parameter 20 I/O CHANNEL to 4
SYSTEM > PARAMETER > (OPRT)
ABC > 20 > NO.SRH > 4 > INPUT
EMAG ES
Service Manual
04.04.14
FANUC
9/49
3.2
Activate USB- front
3
Set parameter 300#0 PCM to 1
3.2
Set parameter 300#0 PCM to 1
Reference: Setting for use of the USB at the EMAG-panel
ABC > 300 > NO.SRH >
> P300#0 PCM > ON:1
EMAG ES
Service Manual
04.04.14
FANUC
10/49
Import of data using the USB port
4
Import of the following data
4.1
4
Import of data using the USB port
4.1
Import of the following data
BY27.mem (Driver for EMAG operating Interface OEM)
FPF0FPDT.MEM (EMAG operating interface OEM)
compiled (EMAG fault messages)
IO_LINK_VLx (Hardware configuration)
Macro_1.MEM (Compile cycles Channel 1)
Macro_2.MEM (Compile cycles Channel 2)
VLx_DCS (Safety PMC)
VLx_PLC (PMC)
4.2
Start the controller by using the boot menu
The controller / machine is switched off. Set the switch MTSW at the board
720-A5 MAIN CPU to position „F“ and power the machine on again.
EMAG ES
Service Manual
04.04.14
FANUC
11/49
Import of data using the USB port
4
Check the setting of the USB – front interface
4.3
After the boot up of the controller the screen will show the following screen:
4.3
Check the setting of the USB – front interface
• Checking the settings of the USB interface on folder E:\ with the button
Settings.
EMAG ES
Service Manual
04.04.14
FANUC
12/49
4.4
Import of data using the USB port
4
Changing the setting of the USB – front interface
4.4
Changing the setting of the USB – front interface
• This can be accomplished with the following menu by pushing this
button.
EMAG ES
Service Manual
04.04.14
FANUC
13/49
4.5
Import of data using the USB port
4
Import of files
4.5
Import of files
• Activate the push button Load
• Mark the file and activate the push button Load in order to load the file.
EMAG ES
Service Manual
04.04.14
FANUC
14/49
Import of data using the USB port
4
Import of files
4.5
Reference:
This must be carried out for each file individually. The loading progress will be
displayed at the status bar how far the action is in progress.
• When all files are loaded follow the menue sequence till you get to reboot the
controller. Wait till the controller has booted up and continue with point 5.
EMAG ES
Service Manual
04.04.14
FANUC
15/49
5
5.1
Import of data with USB interface
5
The following data will be imported
5.1
Import of data with USB interface
The following data will be imported
PMC1_PRM.TXT
PMCS_PRM.TXT
ALL-FLDR.TXT
CNC-PARA.TXT
The following data will be imported using the Fanuc surface. This will be described
in the following chapters.
EMAG ES
Service Manual
04.04.14
FANUC
16/49
6
6.1
Import parameter
6
Import the CNC-PARA.TXT file
6.1
Import parameter
Import the CNC-PARA.TXT file
Reference:
Make sure that prior to import the parameters the parameter 3225 is set to “0“.
Therefore no password is set and all parameters can be imported. In case a password had been set the display field for parameter 3225 is empty and needs to be
set (refer to chapter 6.2).
SYSTEM > PARAMETER
EMAG ES
Service Manual
04.04.14
FANUC
17/49
Import parameter
6
Import the CNC-PARA.TXT file
6.1
> (OPTR) > F INPUT
> EXEC
As long as the import of data is active “INPUT“ will be flashing.
After the import of data is completed “INPUT“ is turned off.
EMAG ES
Service Manual
04.04.14
FANUC
18/49
Import parameter
6
Import the CNC-PARA.TXT file
6.1
Reference:
The message screen will display the following alarm:
Switch machine OFF / On.
• As soon as the controller / machine is switched off set the switch MTSW at
the board 720-A5 MAIN CPU to „0“. Switch the machine / controller on
again.
EMAG ES
Service Manual
04.04.14
FANUC
19/49
7
7.1
Password Safety
7
Set the password for safety CNC- parameter
7.1
Password Safety
Set the password for safety CNC- parameter
As soon as the “EMAG“ picture is displayed on the screen a random button
must be pushed in order for the machine to switch to the FANUC screen.
SYSTEM > PARAMETER > ABC >3225 > NO.SRH
Reference: as long as the parameter 3225 is set to “0“ no password has been set.
EMAG ES
Service Manual
04.04.14
FANUC
20/49
Password Safety
7
Set the password for safety CNC- parameter
7.1
ABC >1320 > INPUT
Reference: If the password is set the view box for parameter 3225 will be empty.
EMAG ES
Service Manual
04.04.14
FANUC
21/49
7.2
Password Safety
7
Delete PMC parameters
7.2
Delete PMC parameters
The following fault will be displayed now in the PMC ALARM:
SYSTEM > PARAMETER > + > + > PMC MAINTE > PMC ALARM
EMAG ES
Service Manual
04.04.14
FANUC
22/49
8
Start the controller with boot menu
8
Clear PMC parameter file
8.1
Start the controller with boot menu
The controller / machine must be switched off. Set the switch MTSW at the board
720-A5 MAIN CPU to „F“. Switch the machine / controller on again.
8.1
Clear PMC parameter file
The screen NC-boot system appears
Hit the push button Close
EMAG ES
Service Manual
04.04.14
FANUC
23/49
Start the controller with boot menu
8
Clear PMC parameter file
8.1
Select menue item 1. IPL MONITOR: confirm by ABC > 1 > INPUT.
Select menue item 3.CLEAR FILE : confirm by ABC > 3 > INPUT.
Select menue item 5.PMC-PARAMETER FILE: confirm by ABC > 5 > INPUT.
EMAG ES
Service Manual
04.04.14
FANUC
24/49
Start the controller with boot menu
8
Clear PMC parameter file
8.1
Request CLEAR FILE OK confirm by ABC > 1 > INPUT .
Menue item 0 END confirm by ABC > 0 > INPUT.
Continue the procedure till the controller proceeds the boot process.
EMAG ES
Service Manual
04.04.14
FANUC
25/49
8.2
Start the controller with boot menu
8
Import of PMC parameters
8.2
Import of PMC parameters
The following files must be imported:
• PMC1_PRM.TXT
• PMCS_PRM.TXT
SYSTEM > PARAMETER > + > + >PMC MAINTE > I/O > (OPRT)
8.3
Import PMC1_PRM.TXT
Select the menue item “MEMORY CARD“ “READ“ and hit the
push button LIST .
EMAG ES
Service Manual
04.04.14
FANUC
26/49
Start the controller with boot menu
8
Import PMC1_PRM.TXT
8.3
Select the menue item PMC1_PRM.TXT and confirm by pushing SELECT.
Execute the file PMC1_PRM.TXT with push button EXEC
Important: make sure the machine is in “Emergency Stop Mode”.
EMAG ES
Service Manual
04.04.14
FANUC
27/49
Start the controller with boot menu
8
Import PMC1_PRM.TXT
8.3
Hit the push button EXEC again
The import of PMC1_PRM.TXT is being executed
Now the status window displays, that the import of parameters is being executed.
EMAG ES
Service Manual
04.04.14
FANUC
28/49
Start the controller with boot menu
8
Import PMC1_PRM.TXT
8.3
Import of PMC1_PRM.TXT has been completed
Now the status window displays, that the import of parameters has been
completed.
EMAG ES
Service Manual
04.04.14
FANUC
29/49
8.4
Start the controller with boot menu
8
Import of PMCS_PRM.TXT
8.4
Import of PMCS_PRM.TXT
Refer to menue item 8.3 and import PMCS_PRM.TXT analog to
PMC1_PRM.TXT.
8.5
Switch machine OFF / ON
Switch machine OFF / ON
• The controller / machine must be switched off. Set the switch MTSW at
the board 720-A5 MAIN CPU to „0“. switch the machine / controller on
again.
EMAG ES
Service Manual
04.04.14
FANUC
30/49
9
Setting of watch and date
9
Switch machine OFF / ON
8.5
Setting of watch and date
MDA>SET /OFS>
>SETTING>PAGE DOWN>
>Date and time > INPUT
EMAG ES
Service Manual
04.04.14
FANUC
31/49
Import of NC- programs
10
Import NC-programs Cannel 1
10.1
10 Import of NC- programs
10.1
Import NC-programs Cannel 1
Reference:
The following must be checked prior to the import:
In order to import the programs for Channel 1 the control for Channel 1 must be
stopped (check PATH1).
The Channel can be selected by pushing the button CHANNEL 1/2.
The path selection must be selected as shown below. This can be selected via
FORE CHANGE and BACK CHANGE.
EDIT > CHANNEL 1/2 > PROG > FOLDER > (OPRT) > +
EMAG ES
Service Manual
04.04.14
FANUC
32/49
Import of NC- programs
10
Import NC-programs Cannel 1
10.1
+ > + >DEVICE CHANGE
EMAG ES
>
MEMORY CARD
Service Manual
04.04.14
FANUC
33/49
10.2
Import of NC- programs
10
Import files
10.2
Import files
F INPUT >
F.GET >
F SET >
EXEC >
EMAG ES
Service Manual
04.04.14
FANUC
34/49
Import of NC- programs
10
Import files
10.2
F INPUT >
As long as the import procedure takes
place “INPUT“ will be blinking.
Reference:
Start again with menue point 10.1
and repeat the import procedure
with all programs. Start again with
F INPUT.
DEVICE CHANGE >
CNCMEM >
NC memory Channel 1
Reference: On the monitor the NC memory Channel 1 will be displayed now.
EMAG ES
Service Manual
04.04.14
FANUC
35/49
10.3
Import of NC- programs
10
Import NC-programs Cannel 2
10.3
Import NC-programs Cannel 2
Reference: the following must be checked prior to the import:
In order to import the programs for Channel 2 the control for Channel 2 must be
stopped. Check PATH2.
The Channel can be selected by pushing the button CHANNEL 1/2.
The path selection must be selected as shown below. This can be selected via
FORE CHANGE and BACK CHANGE.
EDIT > CHANNEL 1/2 > PROG > FOLDER > (OPRT)
EMAG ES
Service Manual
04.04.14
FANUC
36/49
10.4
Import of NC- programs
10
Import NC-programs LIBRARY
10.4
Import NC-programs LIBRARY
Reference: The following must be checked prior to the import:
To import the programs for LIBRARY Channel 1 must be selected at the controller
(Check PATH1). The Cannel can be selected by pushing the button CHANNEL 1/2.
The path selection must be selected as shown below. This can be selected via
FORE CHANGE and BACK CHANGE.
EDIT > CHANNEL 1/2 > PROG > FOLDER >
FOLDER > ABC > INPUT
>RETURN TO UPPER
LIBRARY > ABC > INPUT > (OPRT) > + > FORE CHANGE > BACK CHANGE
EMAG ES
Service Manual
04.04.14
FANUC
37/49
Import of NC- programs
10
Import NC-programs LIBRARY
10.4
+ > + > DEVICE CHANGE >
MEMORY CARD >
F INPUT >
F GET >
F GET >
EXEC >
EMAG ES
Service Manual
04.04.14
FANUC
38/49
DEVICE CHANGE >
Import of NC- programs
10
Import NC-programs LIBRARY
10.4
CNC MEM >
ABC > RETURN TO UPPER FOLDER >
INPUT >
EMAG ES
>INPUT > > PATH1
+>
Service Manual
04.04.14
FANUC
39/49
Import of NC- programs
10
Import NC-programs LIBRARY
10.4
FORE CHANGE > BACK CHANGE >
CNC MEM CHANNEL 1
Reference:
The path selection must be switched to FORE CHANGE and BACK CHANGE in
PATH1
EMAG ES
Service Manual
04.04.14
FANUC
40/49
Check NC-programs
11
Check NC-programs Cannel 1
11.1
11 Check NC-programs
After import the NC-programs must be checked in the individual Channels and
Paths.
11.1
Check NC-programs Cannel 1
PROG > FOLDER > CHANNEL1/2
11.2
Check NC-programs Cannel 2
PROG > FOLDER > CHANNEL1/2
EMAG ES
Service Manual
04.04.14
FANUC
41/49
11.3
Check NC-programs
11
Check NC-programs LIBRARY
11.3
Check NC-programs LIBRARY
CHANNEL1/2 > PROG > FOLDER >
> RETURN TO UPPER FOLDER >
ABC >
INPUT >
11.4
> LIBRARY > INPUT
Check NC-programs register in primitive state
> RETURN TO UPPER FOLDER > ABC > INPUT > PATH1 > INPUT
EMAG ES
Service Manual
04.04.14
FANUC
42/49
Commissioning of the axis
12
Commissioning of the axis
12.1
12 Commissioning of the axis
Reference:
Final end positions are not active jet.
The commissioning is described for one axis and needs to be carried out for all
respective axis of the machine.
12.1
Commissioning of the axis
Prior to set the zero point the axis need to be positioned close to the reference
point position.
Consider the reference point offset in parameter 1240.
MDI > SYSTEM > PARAMETER > ABC > 1815 > NO.SRH
Select with the arrow keys the 1815#APZ for X1 and push ON:1
EMAG ES
Service Manual
04.04.14
FANUC
43/49
Commissioning of the axis
12
Commissioning of the axis
12.1
Parameter 1815#APZ is set to “1” now.
MESSAGE > ALARMS
Switch machine OFF / On.
EMAG ES
Service Manual
04.04.14
FANUC
44/49
Pro Bus System
13
Commissioning of the axis
12.1
13 Pro Bus System
Reference: The option pro bus system must be present. Diagnose parameter
1282#5 “1“.
Import file NETWORK.MEM
MDI > SYSTEM > PARAMETER > + > + > + > + > + > +
PROFI MASTER > ANF >
EMAG ES
Service Manual
04.04.14
FANUC
45/49
Pro Bus System
13
Commissioning of the axis
12.1
(OPRT) > + > ALL RESTORE > EXECUTE > MAIN SWITCH OFF and ON
EMAG ES
Service Manual
04.04.14
FANUC
46/49
Parameter Check Sum Fault
14
Commissioning of the axis
12.1
14 Parameter Check Sum Fault
After commissioning is completed check whether alarm DS5340 is present.
Switch machine OFF / On.
MESSAGE
ALARM- MESSAGE
PROGRAM FOR AUTM.
SW0100 PARAMETER ALLOW OVERWRITING
DS5340 PARAM. CHECK SUM FAULT
If the alarm is present clear the alarm by setting parameter 13730#0.
MDI > SYSTEM > PARAMETER > ABC > 13730 > NO.SRH >
Select parameter 13730#0 via arrow keys and deactivate by pushing OFF:0.
Select parameter 13730#0 via arrow keys and activate again by pushing ON:0.
Switch machine OFF / On.
EMAG ES
Service Manual
04.04.14
FANUC
47/49
Parameter Check Sum Fault
14
Commissioning of the axis
12.1
MESSAGE
ALARM- MESSAGE
PROGRAM FOR AUTM.
SW0100 PARAMETER ALLOW OVERWRITING
EMAG ES
Service Manual
04.04.14
FANUC
48/49
Specification according to work order and machine type
15
Commissioning of the axis
12.1
15 Specification according to work order and machine type
According to the handover protocol / work order all options have to be activated by
setting the appropriate keeprelais.
Please also consider the FANUC Software / Setting System guidance.
Reference:
Find documentation for options selectable by keep relay here:
T:\ELEKTRIK_SOFTWARE\FANUC\___DOKU\Doku_EMAG\Service_Manual\000
_PLC_Manual\000_3xi_Adressaufteilung_neue_Plattform_de.xls
EMAG ES
Service Manual
04.04.14
FANUC
49/49
Download