Calibration of Bridge LTU 11 Lever
Preconditions:
-Engine Stopped and Start Blocked.
-Before calibrating Bridge handle, control must be transferred to ECR
Do not do this with engine running and lever to be calibrated “in command”!
How to calibrate:
1)
Press the “settings” button-> “tap to unlock”->Press “settings” button once more
2)
Following page should be shown
Enter 41436
Select “calibrate lever” :
4)
Put lever in EMERGENCY ASTERN and then press “confirm lever position”
5)
Put the lever in STOP position and press “confirm lever position”
6)
Put the lever in NAVIGATION FULL AHEAD position and press “confirm lever position”
Put the lever in STOP position and press “confirm lever position” and wait for the lever to stop
moving then press “SAVE CALIBRATION”.
8)
Press “HOME” to return to main screen
Finished.