South Xianhua Address: Street,Jinhua,Zhejiang,PR.of China 321016 [email protected] Web: SPORTS MEDICINE 1 Introduction 3 Ti Anchor PART. PART. 6 PART. 9 PART. 3 SPORTS MEDICINE Interface Screw Cutter Blade PART. PART. PART. 2 Diamond Plate 4 PEEK Anchor 7 10 PART. Meniscal Repair System Disposable Radiofrequency Plasma Electrodes PART. PART. 5 8 CONTENT Canloop Plate Non-absorbable Sutures 11 PART. Arthroscopic Approach Cannula SPORTS MEDICINE SPORTS MEDICINE 02 Diamond Plate Solutions for Acromioclavicular joint injury Diamond plate and fixed loop with adjustable knot combo Spindle shape for easy insertion Double-plate fixation conforms to the anatomic mechanical environment Side-opening hole, can be used directly Low profile,reduce discomfort Horizontal 4-hole design, support preset or customizable adjustable loops. Fixed loop with adjustable knot No bone tunnel, guaranteed strength. Elastic fixation, non-rigid fixation The special coracoid threader is convenient for thread passingunder the coracoid. Fixed Loop: Girth fixed, used for fixing one end of bone tissue without bone tunnel. Syndesmosis Injury Solutions Adjustable knot: the circumference is adjustable, the range is 10-280mm, and the diamond plate is used for fixing one end of the bone tunnel. Diamond plate and fixed loop with adjustable knot combo Specification Name Picture Diamond plate ize L* W Product code The thread knot is directly fixed on the side of the fibula without bone tunneling. Elastic fixation between fibula and tibia conforms to anatomical mechanics. H Loop length Fixed loop with adjustable knot Loop length Loop length Note: The adjustable range is :10-280mm Before loading, there is no need to remove the implant, avoiding an extra operation. Special suture passing tool, the wire wrapping around the fibula is simple and convenient. SPORTS MEDICINE SPORTS MEDICINE 03Ti Anchor(MDT01) 03Ti Anchor (MDT04) TM TM CanFix Ti CanFix Ti Head tip and self-tapping design for easy anchoring. Independent thread hole design to avoid suture entanglement. Wide thread thin inner core design for optimal bone handling. Suitable for arthroscopic surgery or open surgery. With and without needle models both available. Smooth bridge design improves wear resistance of sutures. Internal drive design increases handle torque and increases surgical confidence. 2.8 Small diameter can be used for joints. Self-tapping and self-drilling for easy placement. With and without needle models both available. Sp Specification f t Na e Name Suture anchor Ti Product code Product code ize Suture anchor Ti Suture anchor with needle Ti Suture anchor with needle (Ti) Size SPORTS MEDICINE SPORTS MEDICINE 04Peek Anchor(MDP03) 04PEEK Anchor(MDP02) TM CanFix PEEK TM CanFix PEEK Soft tissue fixation, used as an inner row of anchor in rotator cuff repair. Double thread design increases the efficiency of the screwing process and enhances anchor grip Strong pull-out resistance to ensure operation safety. The screwdriver goes deep into the head of the anchor to ensure a stable contact area, which provides stable torque. The torque on the head of the suture is small to avoid the risk of suture breakage during screwing in. Preset two 2# UHMWPE sutures. Size available: 4.5mm, 5.5mm, 6.5mm Specification Name Soft tissue fixation, used as an inner row of anchor in rotator cuff repair. Double-thread design achieves double fixation of cortical bone and cancellous bone, maximizing pull-out resistance. Preset two 2# UHMWPE sutures. Strong pull-out resistance to ensure operation safety. The thread bridge at the head end of the anchor is smooth to reduce suture friction. With and without needle models both available. Size available 4.5mm 5.5mm 6.5mm Specification Name Product Code Size Suture anchor (PEEK) uture anchor (PEEK) Suture anchor with needle PEEK Product Code Size SPORTS MEDICINE SPORTS MEDICINE 04Peek Anchor(MDP09) 04PEEK Anchor(MDP04) TM PEEK Soft tissue fixation, used as an inner row of nails in rotator cuff repair. Full thread design, showing superior pull-out strength in patients with lowbone mass. Cannulated anchor body allows bone marrow stem cells to diffuse to the muscle and footprint areas, allowing bone to grow into and accelerate tendon-bone healing. Preset two 2# UHMWPE sutures to provide reliable guarantee for tendon-bone fixation in shoulder, knee and other parts. TM CanFix PEEK Barbed suture body design, easy to knock in, high pull-out resistance, can effectively reduce suture loose and slippage. Preset two 2# UHMWPE sutures. Extra-long handle design for easy labral implantation. 3.0mm diameter, for the repair of glenoid labrum injury. The internal drive mode greatly enhances the maximum failure torque of he anchor and is available in 4.5 and 5.5mm diameters. Specification Name Suture anchor Specification Product code PEEK Size Name Kno k in suture anchor (PEEK) Product code ize SPORTS MEDICINE SPORTS MEDICINE 04PEEK Knot Free Anchor(MDP06) TM PEEK TM Soft tissue fixation, used as outer row nails in rotator cuff repair Double-thread design achieves double fixation of cortical bone and cancellous bone, maximizing pull-out resistance. At least 3 sutures can be passed at the same time to improve the operation efficiency The thread is rounded and blunt to reduce the cutting of the thread to the suture during screwing in. Size available:4.5mm, 5.5mm, 6.5mm Specification Name Knock-in knot free suture anchor(PEEK) 04PEEK Knot Free Anchor (MDP08) Product code Size PEEK True knot-free repair: a better option for rotator cuff double row technology. Separate anchor head and anchor body design, easy to adjust suture tension. The anchor body is designed with full thread, showing superior pull-out strength in patients with low bone mass. The cannulated design promotes bone in growth while reducing the implantation of PEEK material. Can be used flexibly in combination with sutures. Conical handle for easy screw-in grip Double-sided suture slot design for easy suture management. Size available: 4.75mm, 5.5mm Specification Name Knock-in knot free suture anchor(PEEK) Product code Size SPORTS MEDICINE SPORTS MEDICINE 04PEEK Knot Free Anchor (MDP01) TM CanFix PEEK CanLoop™ Fixed Separate anchor head and anchor body design, easy to adjust suture tension. Barbed suture body design: easy to knock in, high pull-out resistance, can effectively prevent loose suture and slippage. Knot-free design, reducing suture incision, easy to operate Easy to hold knock-in handle design; double-sided suture slot design for easy suture management. Available in diameters of 2.5, 2.9, and 4.5mm, for repair of glenoid labrum injury, double-row external row fixation. Specification Name Knock-in knot free suture anchor(PEEK) 05Canloop-Fixed Plate Product Code Size Still the "gold standard" for femoral fixation in cruciate ligament reconstruction.The strength of the braided wire loop is comparable to similar products, and the ultimate tensile force is as high as 2000N. Fatigue test is carried out after implantation, the displacement of suture loop is equivalent to international brand. Pre-set 5# super strong pulling wire to ensure the stability of the product during the transfer of the implants. Specification Name anloop-fixed Product code Size SPORTS MEDICINE SPORTS MEDICINE 06Interface Screws & Sheathed Screws 05Canloop-Adjustable Plate CanLock™ PEEK CanLoop™ AD&RC The graft can completely fill the femoral tunnel and promote tendon-bone healing. The effect of the wire loop locking mechanism is reliable, and the postoperative displacement of the wire loop is small. Effectively avoid postoperative bone tunnel expansion caused by "bungee effect" and "wiper effect". Pre-set 5# super strong pulling wire to ensure the stability of the product during the transfer of the implants. Side opening of reinforced plate makes implantation more convenient and fast. Reinforced plates provide safe and effective solution for revision surgery orcortical bone tunnel burst. Specification Name Product code The screw is gradually thickened to enhance the fixation strength of the tibial end. Blunt thread design reduces the cutting of the tendon by the screw during screwing in With the use of PEEK nail sheath, it can completely avoidthe cutting of the tendon by the screw. Window horizontal grain design, stronger grip. Specification Name Interface screw Size Adjustable plate Reinforced plate Sheathed screws Product code ize Name Screw&health combo Product code ize SPORTS MEDICINE SPORTS MEDICINE 07 All-inside meniscal repair system Smaller PEEK anchor combined with #2-0 super strong polyethylene sutures Adjustable depth gauge rod Various angles, depth control Reinforced needle rod 360°excitation ring Human engineering design handle Special supporting tool CanFast™ SYETEM Human engineering design handle, more convenient to hold. 360°excitation ring, T1, T2 fixed block are active excitation. Adjustable depth control rod to ensure precise puncture. Reinforced low-profile needle bar improves puncture efficiency. Smaller implants, reducing damage to the meniscus. Various tip angles available (curved, reversed and straight). The end of the puncture needle is equipped with scales, and the puncture depth can be directly determined under arthroscopic. Specification Name Product code Size curved Menis al repair device straight reversed curved Designed for the fresh treatment of meniscal tears. File head multi-helix tooth design, stable cutting, durable wear. Human engineering design,fine control, easy operation. The unique design of the curved cutting edge of the push knot thread cutter provides a smooth cutting experience. SPORTS MEDICINE SPORTS MEDICINE 08Repair Sutures 09Disposable Sterile Cutter Heads Sharp toughness treatment technology, efficient cutting Laser welding, high-strength torque, no chips. Micron-level tolerances among tubes , which can rotate freely and do not generate heat. High strength stainless steel, strength guaranteed Linvatec Smith&Nephew Stryker 3 major types connectors Non-absorbable surgical sutures CanCut™ SYSTEM The stitches are woven from UHMWPE yarn. Cutter or burrs for "cutting or polishing" tissue. Cutting is completed by the drive assembly at a certain speed and a certain direction of rotation. The handle of the hand control or the pedal controls the start, stop and rotation direction of the cutter head. A necessity for every arthroscopic surgery A necessity for microscopic synovial surgery. A necessity for endoscopic ligament injury soft tissue injury surgery. A necessity for Endoscopic meniscus surgery. One-time use to avoid cross-infection of patients. Variety of stitching ways: round, round flat, flat, loop Unique surface coating treatment and multi-strand braiding technology have better suture softness and higher strength. Wire loops are more efficient in tendon braiding. Specification Name Product code Size white reverse triangle needle,1/ arc Round suture white reverse triangle needle white round needle straight Round flat suture Multi-toothed cutter head design Non-serrated Cutter:Meniscus and synovial tissue were cut and cleared,and the edges were more tidy. blue/white blue/white Suture loop arc white round needle,straight Serrated cutter Increased efficiency of cutting and planing meniscus, synovial tissue. Faster cutting speed Super Strong Double Serrated Cutter: One blade multi-purpose,strong cutting ability. Spherical Grinding Burr: Excision of bone is more focused. Cylindrical Grinding Burr Larger contact area, more efficient bone removal. SPORTS MEDICINE SPORTS MEDICINE 10Disposable RF Plasma Surgical Electrodes Specification Product code Picture Name Length Diameter Connector Generator connector Negative pressure line Super strong double serrated cutter High temperature alloy electrode tip Non-serrated cutter errated cutter Ergonomic handle Linvatec Cylindrical grinding burr Cable pherical grinding burr CanCut™ SYSTEM Cutter or burrs for "cutting or polishing" tissue. Cutting is completed by the drive assembly at a certain speed and a certain direction of rotation. The handle of the hand control or the pedal controls the start, stop and rotation direction of the cutter head. A necessity for every arthroscopic surgery. Super strong double serrated cutter Serrated cutter Non-serrated cutter Cylindrical grinding burr Smith&Ne phew A necessity for microscopic synovial surgery. A necessity for endoscopic ligament injury soft tissue injury surgery. A necessity for endoscopic meniscus surgery. One-time use to avoid cross-infection of patients. Multi-tooth cutter head design Round electrode:Applied to knee joint meniscectomy, membrane resection, cruciate ligament stump removal, intercondylar concave formation, chondroplasty, ligament contracture, cruciate ligament anatomical footprint area marking. SPORTS MEDICINE SPORTS MEDICINE 11 Sheet electrode Applied to shoulder arthroscopic acromion decompression, decompression, subacromial bursa removal, distal clavicle resection, glenohumeral joint surgery, rotator cuff surgery, frozen shoulder release, joint capsule contraction. Spiky electrode: It is specially designed for arthroscopic surgery of wrist, ankle, elbow and other small joints. Arthroscopic Access Cannula Ring electrode: It is mainly used in cartilage plastic surgery, and can perform precise cartilage ablation surgery. Specification Name Product code Length External diameter Suction Y Y Y Disposable RF Plasma Surgical Electrode N Y Picture Silicone sleeve Bilateral low notch contour design increases the operating space under arthroscopy The flexible material avoids soft tissue damage and provides flexibility in handling Fully enclosed design to reduce liquid leakage caused by equipment in and out. Applicable to joints such as shoulder, knee, and hip. Thread sleeve Fully enclosed design to reduce liquid leakage causedby equipment in and out. Transparent tube for easier observation of instruments and sutures The new thread design provides better intra-jointstability. Human engineering design, easy to operate during the operation. Specification Name Silicone sleeve N Thread sleeve Product code Size