Manual of GAA21750AK3 elevator service tool www.escalatorparts.cn —————————————————————— Mechanical Design 2 Mechanical Design The mechanical design of the Service Tool is shown in Flgure 21. The Service Tool consists of two rows display with 16 columns each And a keyboard with 16 keys. The Tool is connected to the LCB_II over a RS 422 serial communication line. MCS-LCB_II 调试方法 MCS-LCB_II Service Tool Manual Main Level Keys ———————————— M - MODULE F - FUNCTION S - SET LCB II – Menu System=1 Tools=2 Shift Keys №. M F S 7 8 9 7 7 7 4 5 6 7 7 7 1 2 3 7 7 7 0 GO clea 7 7 7 0 1 2 3 - OFF ON UP DOWN 4 5 6 7 8 9 - DISP IN SEL OUT DISP STATE ENT CALL TEST ENTER GO BACK Shift key www.escalatorparts.cn Short Keys -S4 -S5 -S6 -S7 -S8 -S9 Hex Keys -A -B -C -D -E -F 3 —————————————————————— 3 Tree Structure Tree Structure All Service tool functions are organized under the tree –structure – structure Which you can see in Figure 3-1. It is divided in a SYSTEM path ,where you have access to the main service Tool functions – STATUS (system monitoring) - TEST (event monitoring tests) and - SETUP(setup of system environment),and in a TOOLS path. The TOOLS pass contains the Service Tool functions which supports installation and maintenance of the elevator. LCB_II - Menu SYSTEM - Menu STATUS - Menu TEST - Menu TOOLS - Menu SETUP - Menu Search IO Calls Event Install Erase IO Inputs Diagnosis RSL Setup INST Outputs Part Allowed Opr.Memory Group RSL POS ICSS Selftest DCS Run Cmd www.escalatorparts.cn ELD 4 —————————————————————— 4 LCB_II Menu System Menu System 4.1 OVERVIEW The Menu System allows you to access the single Server Tool functions if you choosethe right path through the Tree-Structure by pressing the displayed key.(number 1,2,3… 8) If there is only one number to choose .you can call the function also with the Shift Key ‘ENTER’. You can toggle between the different Menus using the „GO ON‟ or „GO BACK‟ key if the „>‟character indicates a hidden menu. The „CLEAN‟ key lets you jump one step back. If you want to jump back to the one of the three Main Level of the architecture,(MONITOR, FUNCTION or SET) you can do it with the „M‟,‟F‟ or „S‟ Main Level Key. The LCB_II Menu System is shown in Figure 4 – 1. www.escalatorparts.cn Power on SELF TEST - OK - MECS - MODE M M LCB_II - Menu System=1 Tools=2 1 F 2 SYSTEM – Menu > Status = 1 Test= 2 TOOLS – Menu > 1 = Search IO SYSTEM – Menu > Setup = 3 TOOLS – Menu > 2 = Erase IO TOOLS – Menu > 3 = Setup INST 1 S 2 STATUS – Menu > Calls = 1 Input = 2 TOOLS – Menu > 9 = Opr.Memory 3 SETUP – Menu > Install =1 RSL = 2 TEST – Menu > Events = 1 Diag = 2 STATUS – Menu > Output = 3 Group = 4 TEST – Menu > Part = 3 RSL = 4 STATUS – Menu > ICSS = 5 Cmd = 6 SETUP – Menu > Allowed = 3 POS = 4 SETUP – Menu > DCS – RUN = 5 ELD=6 TEST – Menu > Selft = 5 1 INSTALL – Menu > 01 System 2 Allowed – Menu > 01 Enable Allowed – Menu > 02 Cut Call Allowed – Menu > 03 Card_Rd Figure 4 – 1 :Menu System www.escalatorparts.cn 4.1.1 System Path M LCB_II - Menu 1 F 2 System - Menu 2 1 S Status - Menu 1 Calls 2 Input 3 Output 4 Group 5 ICSS 6 Cmd (31) (33) (34) (35) (36) 1 Event 2 Diagnosis 3 Part 4 RSL 5 Self test System - Menu (16) (38) (40) (42) (43) (44) (36a) Setup - Menu (37) 1 Install - Menu 1 System 2 OCSS 3 Group 4 Drive 5 Doors 6 Position Ref. 7 Cargo 8 Emergency 9 Security Go on (转下页) www.escalatorparts.cn (61) 3 Test - Menu (37) (28) (15) Test (47) 2 RSL 3 Allowed - Menu Legend: 1 (50) 1 Enable 2 Cut Call 3 Card Reader Service Tool Key. Menu System Function 4 POS 5 DCS Run 6 ELD (56) (58) (16) Page Number Figure 4 – 2:System Path Overview 4.1.2 (60) Tools Path M LCB_II - Menu 1 F System - Menu 2 Tools - Menu (61) 1 Search IO 2 Erase 3 Setup INST 4 Opr. Memory S Legend: 1 Service Tool Key Function Menu System (16) Page Number Figure 4 – 3:Tools Path Overview. www.escalatorparts.cn (52) 4.2 LCB_II – Menus 4.2.1 Power On SELF TEST - OK – MECS - MODE M Figure 4 – 4 : Power On Display / Keys 4.2.2 LCB_II - Menu After Power On the Service Tool software runs an internal selftest. The display shown in figure 4 – 4 indicates a synchronized communication with the LCB_II and a successful selftest. The Service Tool is in operation now. M - Key MODULE: Transition to the LCB_II – Menu. LCB_II – Menu System=1 Tools=2 Key Sequence M 1 LCB_II - Menu System=1 Tools=2 2 Go on Figure 4 - 5 LCB_II – Menu / Keys www.escalatorparts.cn 2 1 M 1 Key 1: transition to the SYSTEM – Menu Key2 : transition to the TOOLS – Menu 2 2 shift Key UP :display the current <toggle key> Controller Type and Drive Type. (UP) Go on Go on (GO BACK) 1 (ON) M www.escalatorparts.cn Key GO ON :displays the current <toggle key> stop signal(s) LCB_II – Menu MCS120 Sol.V > LCB_II – Menu Stop on : U / DIS (see document : Service Tool reference List / Info Messages) Shift key ON: displays the current state of the programmable Short Key S9 Shift key OFF: removes display See:4.3 Short Keys Shift key and MONITOR: Displays the revision and date of the Service Tool Firmware. LCB_II – Menu SVT – Key PROG: on VERS:GOD616G28 6 – JUL - 1990 4.2.3 SYSTEM - Menu M-1 Key Sequence 1 2 3 SYSTEM – Menu > Status=1 Test=2 M Figure 4 – 6 :SYSTEM – Menu / Keys www.escalatorparts.cn 1 - Key 1: Transition to the STATUS – Menu 2 - Key 2: Transition to the TEST – Menu 3 - Key 3: Transition to the SETUP – Menu M - Key MODULE: back to LCB_II – Menu (level M) clear - Key CLEAR: back to LCB_II – Menu (one step back) Clear 4.2.4 STATUS – Menu M–1–1 Key Sequence 1 5 goon STATUS – Menu > Call = 1 Input = 2 goon (go back) M 1 6 goon goon - Key1 or Key2: Call of service Tool function Calls or input. Key3 or Key4: Call of service Tool function Output or Group. Key5: Call of service Tool function ICSS. Key6: Call of service Tool function Cmd. - Key GOON / Shift Key GOBACK: Toggle through STATUS – Menu notice: („>‟indicates Menu – Toggle) - Key MODULE: back to LCB_II Menu (level M) F - Key FUNCTION: back to SYSTEM - Menu (level F) - Key CLEAR: back to SYSTEM - Menu (one step back) clear STATUS – Menu > Output = 3 Group = 4 M clear www.escalatorparts.cn F 4.2.5 TEST – Menu Key Sequence M–1–2 1 5 TEST – Menu > Events= 1 Diag=2 clear goon Figure 4 – 8: SETUP – Menu / Keys 1 - 5 goon goon www.escalatorparts.cn F Key 1 or 2: Transition to the Events – or Diagnosis – Func. Key 3 or 4: Transition to the Part – or RSL – Func. Key 5: Call of Selftest. - Key GOON / Shift Key GOBACK: Toggle though SETUP - Menu notice: („>‟indicates Menu – Toggle) M - Key MODULE: back to LCB_II – Menu (level M) F - Key FUNCTION: back to SYSTEM - Menu (level F) clear M - Key CLEAR: back to SYSTEM - Menu (one step back) TEST – Menu > Part = 3 RSL = 4 clear 4.2.6 SETUP - Menu Key Sequence M–1–3 1 5 goon goon SETUP – Menu > Install = 1 RSL = 2 (GOBACK) Figure 4 – 9:SETUP – Menu / Keys - 1 6 goon goon (GOBACK) www.escalatorparts.cn M F clear Key 1 or 2: Transition to the INSTALL – Menu or RSL – Func. Key 3 or 4: Transition to the ALLOWED – Menu or Pos – Func. Key 5 or 6: Call of Service Tool Function DCS – Run or ELD – Func. - Key GOON / Shift Key GOBACK: Toggle through SETUP - Menu Notice: („>‟indicates Menu – Toggle) M - Key MODULE: back to LCB_II - Menu (level M) F - Key Function: back to System - Menu (level F) clear - Key CLEAR: back to System - Menu (one step back) SETUP – Menu > Allowed = 3 POS = 4 4.2.7 Install - Menu M–1–3-1 Key Sequence 1 clear 9 … Install Menu 01 System > Figure 4 – 10:Install – Menu / Keys 9 … M F (ENTER) goon goon (GOBACK) M F S clear www.escalatorparts.cn S - Key … Key 9: Call of the Service Tool function INSTALL –SYSTEM … Install – Security.(Please call Install – Test with Key ENTER) - Shift Key ENTER: Call of the displayed Service Tool function. clear 1 goon goon - Key GOON / Shift Key GOBACK: Toggle through INSTALL - Menu notice : („>‟indicates Menu – Toggle) - Key MODULE: back to LCB_II – Menu (level M) - Key FUNCTION: back to SYSTEM – Menu (level F) - Key SET: back to SETUP – Menu (level S) - Key CLEAR: back to SETUP – Menu (one step back) clear 4.2.8 ALLOWED – Menu M–1–3-3 Key sequence 1 clear 3 ALLOWED – Menu 01 Enable (ENTER) > goon goon (GOBACK) Figure 4 – 11: ALLOWED – Menu / Keys 1 clear 3 … F goon - Key GOON / Shift Key GOBACK: Toggle through ALLOWED - Menu M - Key MODULE: back to LCB_II – Menu (level M) F - Key FUNCTION: back to SYSTEM – Menu (level F) S - Key SET: back to SETUP _Menu (level S) clear S - Key 1: Call of the Service Tool function Allowed - Enable … Key 3: …or the other 2 function of the ALLOWED - Menu - Shift Key ENTER: Call of the display Service Tool function (ENTER) goon www.escalatorparts.cn M - Key CLEAR: back to SETUP_ Menu (one step back) clear 4.2.9 TOOLS – Menu M-2 Key sequence 1 clear 9 TOOLS – Menu 1= Search IO (ENTER) > goon M goon clear (GOBACK) Figure 4 – 12:TOOLS – Menu / Keys - Key 1: Call of Service Tool function Search IO. - Key 2,3 or 9: Call function Erase IO, SETUP INST or Opr. Memory 1 9 … clear - Shift Key ENTER: Calls the displayed Service Tool function. (ENTER) goon goon (GOBACK) M clear www.escalatorparts.cn - Key GOON / Shift Key GOBACK: Toggle through TOOLS - Menu notice: („>‟indicates Menu – Toggle). - Key MODULE: back to LCB_II – Menu (level M) - Key CLEAR: back to LCB_II – Menu (one step back) TOOLS – Menu > 02 = Erase IO 4.3 Short Keys S4 – S9 Short Keys The Short Keys provide direct access to certain, often used Service Tool functions, eliminating the need to step through the menu structure. The Service Tool functions Input, Call, Install, Alter and Events are assigned to the Standard Short Keys S7 (Shift 7),S8 (Shift 8),S4 (Shift 4),S5 (Shift 5)and S6 (Shift 6). Short Key S9 (Shift 9) is a free programmable key to store any posi tion of the Tree – Structure as a sixth Short Key. Once you have stored S9 (by pressing S9at the desired position)you Can reset it only on level M (LCB_II – Menu) LCB_II Menu System = 1 Tools = 2 7 DISP STATE M 7 8 9 F 4 5 6 S 1 2 3 0 Goon clear Figure 4 – 13 : Short Keys S4 – S9. www.escalatorparts.cn 8 ENT CALL 4 5 DISPIN SELout 1 2 S4 = Install S5 = RSL S6 = Event S7 = Input S8 = Calls S9 = PROG 9 TEST 6 3 4.3.1 Standard Short Keys LCB_II - Menu TOOL - Menu SYSTEM - Menu Search IO STATES - Menu TEST - Menu SETUP - Menu Erase IO S8 Calls S6 S4 Events Install Setup INST Inputs S7 Diagnosis S5 RSL Opr.Memory Figure 4 – 14: Standard Short Keys S4, S5, S7, S8 and S9. Example: A – 00 IDL ST ] [ ] [ -----------------------------------u d l ux ------------------------------------ 8 The current function may be STATUS / Output - Short Key S8: Direct call of function STATUS / Calls. (see chapter: 5.1.2) (S8) A – 00 IDL ST ] [ ] [ ----------------------------------------u d l ux ----------------------------------------- www.escalatorparts.cn 4.3.2 Programmable Short Key S9 Short Key PROG S9 LCB_II - Menu TOOL - Menu SYSTEM - Menu Search IO STATES - Menu TEST - Menu SETUP - Menu Erase IO S8 Calls S6 Events S4 Install Setup INST Inputs S7 Outputs 9 Diagnosis Part 5 S5 RSL Opr.Memory Allowed Figure 4 – 15: Standard Short Keys and Short Key S9 In Figure 4 – 15 you can see the function of Short Key S9. In this example the function STATUS / Outputs is set to the Short Key S9 function. Now S9 is acting like a Standard Short Key. In Figure 4 – 15 the current position is SETUP / RSL. Now you can call function STATUS / Output with Short Key S9. www.escalatorparts.cn Example Function STATUS / Output (see chapter: 5.1.4) Should be set as a Short Key function: First you have to call STATUS / Output. A – 00 IDL ST ] [ ] [ ----------------------------------------u d l ux ----------------------------------------- 9 (S9) Short Key S9: Position STATUS / Output is set to the Short Key S9 function - Key MODULE and Shift Key ON: The status of Store Key S9 is displayed on the LCB_II – Menu. 1 M LCB_II - Menu SVT – Key PROG : on (ON) notice : - Short Key S9 and LCB_II – Menu: Reset of Short Key S9. 9 LCB_II – Menu SVT – Key – PROG : off (S9) IO I AD P AD P >0000_ _ _ _ _ _ _ _ _ _ _ 9 (S9) www.escalatorparts.cn Now you can toggle between any function (SETUP / RSL (see chapter: 5.2.2)) and STATUS / Output. - Short Key S9: Call of function STATUS / Output. A – 00 IDL ST ] [ ] [ u d l ux_ _ _ 5 —————————————————————— Service Tool Functions 5 Service Tool Functions All the Service Tool functions are divided into 4 groups, the STATUS, TEST, and SETUP and Tools functions. LCB_II – Menu System = 1 Tools = 2 SYSTEM – Menu > Status = 1 Test = 2 STATUS – Menu > Call = 1 Input = 2 STATUS – Functions TEST – Menu > Events = 1 Diag = 2 SETUP – Menu > Install = 1 RSL = 2 TEST – Functions SETUP – Functions Figure 5 – 1: STATUS-, SETUP-, and TOOLS- paths www.escalatorparts.cn TOOLS – Menu > 1 = Search IO TOOLS - Functions 5.1 STATUS – Functions ************* Key Sequence M–1–1 STATUS – Menu > Call = 1 Input = 2 goon STATUS – Menu > Output = 3 Group = 4 STATUS – Menu > ICSS = 5 CMD = 6 clear 1 6 2 A-00 IDL ST ] [ ] [ C> U00D00 A 1C 3 4 5 Calls – function CMD – Func. A–00 IDL ST ] [ ] [INS ?? dw DFC Input – Function A-00 IDL ST ] [ ] [ u d l ux A-00 IDL ST ] [ ] [ **************** ICSS IS ONLINE ICSS2 IS OFFLINE Output – Function Group – Function ICSS – Func. Figure 5 – 2 : STATUS – Functions In the following all the STATUS – functions are explained. There are the Calls,Input,Output,Group,ICSS and CMD functions to control the elevator calls and monitor the software status and system I/O „s. A – 00 IDL ST ] [ ] [ The first row always displays the Software Status. It gives information about - the car identifier in group - the direction of the moving cabin. - the current position. - the Operational Control software State, and - the Front and Rear Door State. C> U00D00 A 1 C ------------------------------ Please find in chapter 5.1.1 the exact description of The Software Status Display (Row one) Figure 5 – 3:Software Status www.escalatorparts.cn A-00 IDL ST ] [ ][ ?:CLD1 ?:CLD2 5.1.1 Software Status Display Car identifier A B C A – 00 IDL ST ] [ ] [ C> U00D00 A 1C Direction A – 00 IDL ST ] [ ] [ C> U00D00 A 1C Position A – 00 IDL ST ] [ ] [ C> U00D00 A 1C www.escalatorparts.cn Description stop / direction not defined car is moving in UP direction car is moving in DOWN direction 00 ** Description actual level (level 0) position not defined OCSS mode IDL Description current OCSS – mode (ldle) see document: Service Tool Reference List / Operation Modes MCSS status Description ST Doors states ][][ A – 00 IDL ST ] [ ] [ C> U00D00 A 1C First car of group / Simplex second car in group third car in group — U D A – 00 IDL ST ] [ ] [ C> U00D00 A 1C A – 00 IDL ST ] [ ] [ C> U00D00 A 1C Description current MCSS – state (Stop) See document: Service Tool Reference List / Motion States Description front / rear door state: ] [ for Closed [ ] for Open < >for Opening >< for Closing ** for door state not defined Event Messages in Status Display A – 00 INS IN ] [ ] [ C> U00D00 A 1C A – 00 > TCI – LOCK ! C> U00D00 A 1C In additional a blinking Event Message will be displayed during Software Status Display if one of the following events occurs and The elevator is blocked. Examples: Event Message >TCI – LOCK ! >LS-FAULT ! >start DCS ! >ACS is on ! >1LS + 2LS ! Leave Top of Car „ function on 1LS / 2LS check negative Door Check Sequence not opr. yet Anti Creeping Switch is operated 1LS and 2LS is operated (see document: Service Tool Reference List / Event Messages) www.escalatorparts.cn 4.1.2 Call – Function Key Sequence Short Key A – 00 IDL ST ] [ ] [ C> U00D00 A 1C Figure 5-4: Calls – Function Enter a call 1) - you can enter a Car Call ,UP Hail Call, Down Hall Call or Emergency Hospital Call - Monitoring of: - number of Upper and Lower Call Demands - Load Status - number of cars available in group - power supply Calls Call Type / Level Number 1) C U D E Car Call Up Hall Call Down Hall Call Emergency Hospital Call 2) 02 entered call (level 2) A u 00 NOR FR ] [ ] [ C>02 U00D00 A 1C goon Calls S8 In Figure 5-4 you can see the display of function Calls. The first row displays the Software Status (see: 5.1.1). The second row controls the Elevator Calling System. 2) goon M–1–1-1 - Key GOON / Shift Key GOBACK : Toggle trough the Call Types C–U–D–E (GOBACK) clear 2 (ENTER) www.escalatorparts.cn - Key number for desired level (2) - Shift Key ENTER: Termination to enter the desired (type, level) call 1) 2) A u 00 NOR FB ] [ ] [ C> U01D00 A 1C Call Demands 1) 01 number of UP-Call demands 2) 00 number of DOWN-Call dements Load Status A u 00 NOR FR ] [ ] [ C> U01D00 A 1C A F P O D ANS load full load peak load overload default load Cars Available In Group A u 00 NOR FR ] [ ] [ C> U01D00 A 1C A u 00 NOR FR ] [ ] [ C> U01 D00 A 1C www.escalatorparts.cn 1-3 number of cars available in group C E Power Supply Normal power supply Emergency power supply 4.1.3 Input – Function Key Sequence Short Key M–1–1–2 Input S7 In Figure 5-5 you can see the display of function Input. A – 00 IDL ST ] [ ] [ ins es dw DFC The first row display the Software Status (see: 5.1.1). Figure 5-5:Input – Function The second row monitors the System Inputs - Lower case letters of the input name stands for „Function = OFF‟ and upper case letters for „function = ON‟ - Up to four signals are displayed in one row .you can skip to the next / previous group with Key GOON / GOBACK. - Each group is assigned to a functional block. Both can be displayed with Shift Key ENTER. Please refer to the list of available System Inputs. (see document: Service Tool Reference List) goon goon - Key GOON / Shift Key GOBACK: Skip to the next / previous group of the System Inputs. (GOBACK) A – 00 IDL ST ] [ ] [ md aes 2 (UP) www.escalatorparts.cn 3 (DOWN) - Shift Key UP / Shift Key DOWN: <toggle keys> Row one: Display of the functional block and the current group. Block :System Group 1 :Safety Chain SY1 Safety Chain ins es dw DFC 5.1.4 Output - Function Key Sequence M–1–1-4 In Figure 5-7 and 5-8 you can see the display of Function Group. A – 00 IDL ST ] [ ] [ B – 03 IDL ST ] [ ] [ Figure 5-7:Group – Function The first row displays the Software Status. of the Controller the Service Tool is connected with. The second row displays the Software Status of one of the other Controllers in the group. (see :5.1.1 Software Status) A – 00 IDL ST ] [ ] [ *** *** *** *** Figure 5-8:Group - Function (Simplex) goon goon - Key GOON / Shift Key GOBACK: Skip to the next / previous Controller in the group. (GOBACK) A – 00 IDL ST ] [ ] [ C – 07 IDL ST ] [ ] [ www.escalatorparts.cn 5.1.5 Group – Function Key Sequence M- 1 – 1 – 4 In Figure 5 – 7 and 5 – 8 you can see the display of function Group. A – 00 IDL ST ] [ ] [ B – 03 IDL ST ] [ ] [ Figure 5-7: Group – Function The first row displays the Software Status. of the controller the Service Tool is connected with. The second row displays the Software Status of one of the other Controllers in the group. (see: 5.1.1 Software Status) A – 00 IDL ST ] [ ] [ *** *** *** **** Figure 5-8: Group – Function (Simplex) goon goon - Key GOON / Shift Key GOBACK: Skip to the next / previous Controller in the group. (GOBACK) A – 00 IDL ST ] [ ] [ C – 07 IDL ST ] [ ] [ www.escalatorparts.cn 5.1.6 ICSS - Function Key Sequence M– 1 – 1 - 5 In Figure 5-9 you can see the display of function ICSS. ICSS ICSS2 IS IS ONLINE OFFLINE The first row displays the status of first ICSS. The second row displays the status of the second ICSS. Figure 5-9 : ICSS - Function www.escalatorparts.cn 5.1.7 Command – Function Key Sequence The first row displays the Software Status (see : 5.5.1) A – 00 IDL ST ] [ ] [ F : CLD1 R : CLD1 goon goon M–1–1-6 The second row displays the Commands which are send to the internal Subsystems. (see document : Service Tool Reference List / Commands) - Key GOON / Shift Key GOBACK: Skip to the next / previous group of commands (GOBACK) A – 00 IDL ST ] [ ] [ MC: GoTo To : 00 1) Display Field 1) 2) CLD1 3) CLD2 A – 00 IDL ST ] [ ] [ F : CLD1 R : CLD2 2) Discription Software Status command for front door command for rear door 3) 1) Au00 NOR FR ] [ ] [ MC : GoTo To : 00 2) www.escalatorparts.cn 3) Display Field Discription 1) 2) GoTo 3) 00 Software Status Motion command Actual Target (**=invalid) M–1–2 TEST – Menu > Event = 1 Diag = 2 1 2 3 4 5 clear 00000 total runs 00000 minutes on Event – Function Diagnosis – Function Part – Function RSL – Funtion Figure 5-10: TEST – Functions In the following all the TEST – functions are explained. There are the Events, Diagnosis, Part, RSL and Selftest functions, which are the most used functions for service and maintainace. Short Key S6 is assigned to call the Event – function. The Diagnosis – function operates the diagnosis parameter stored in The EEPROM after Power – OFF. Part displays the configuration number of EPROM and EEPROM, RSL and Selftest are functions to test the hardware of the LCB_II. www.escalatorparts.cn Selftest – Func. 5.2.1 Event – Function Key Sequence Short Key 00000 00000 M–1–2–1 Event S6 The Event – Function support the maintenance of The elevator. It displays - the total number of runs - the elapsed time since Power On - information about each event: - event text - the number of event - the elapsed time since last occurrence - the car position where the last event occurred Please refer to the list of Event Messages: (see document: Service Tool Reference List) total runs minutes on 1) global information 00000 00000 total runs minutes on 1) 00000 number of elevator runs 2) 00000 number since Power On 2) goon goon - Key GOON / Shift Key GOBACK: Skip through the list of recorded event messages. (GOBACK) 00000 00000 total runs minutes on No events logged 00000 00000 total runs minutes on 0400 c002 RSL parity t00001 p** No a) no event recorded www.escalatorparts.cn more event logged b) one event recorded Event logging 1 0400 c002 2) RSL parity t00001 p** 3) event logging 4) 1) 1.row 2) 002 3) 00001 4) ** event text number of event since last occurrence elapsed time since last occurrence (minutes) car position where event occurred finally (** = position not defined) Event reset - Shift Key ON: Reset the displayed event. 1 Erase Value 0400 RSL (ON) clear ? parity - Shift Key ENTER: Termination of the reset Function. (ENTER) Erase Value done ! ? - Shift Key UP: Reset the entire event Logging. 2 (UP) clean Erase Events n=0 y=1 > 1 (ENTER) clear ? - Key 1 and ENTER and Key 2 and ENTER : Termination of the reset Function. 2 (ENTER) clear www.escalatorparts.cn Erase Events Please wait! - Key CLEAR: back to Test - Menu ? 5.2.2 Diagnosis - Function Key Sequence M–1–2-2 In Figure 5-12 you can see the display of function Diagnosis. The first row displays the name of the current diagnosis parameter. 01 DIAG ACT - T 000 : 00 : 00 : 34 Figure 5-12 : Diagnosis - Function The second row shows the value of the diagnosis parameter. - You can skip to the next / previous diagnosis parameter with Key GOON / GOBACK - With Key UP you can display a short legend for the time values. - The displayed parameter can be reset to zero using the key sequence ON/UP and ENTER. Please refer to the list of Diagnosis Parameters. Diagnosis Parameter display Example of a time parameter 1) 2) 02 DIAG TOT - T 003 : 17 : 22 : 57 3) 4) 5) Display Field 1) 02 2) TOT-T 3) 003 4) 17 5) 22 6) 37 Description Parameter no. Parameter name No. of months No. of days No. of hours No. of minutes Display Field Description 6) Example of a time parameter 1) 2) 03 DIAG UP - CNT 000000079 3) www.escalatorparts.cn 1) 03 2) UP-CNT 3) 000000079 Parameter no. Parameter name No. of occurrences Diagnosis parameter reset - Shift Key ON: Reset the displayed event 1 Erase Value ? 02 DIAG TOT - T (ON) - Shift Key ENTER: Termination of the reset function. clear (ENTER) 2 - Shift Key UP displays a short legend of the time value – if a time – value was displayed before. (UP) 2 - Shift Key UP(a 2,time): Resets the entire event Logging. (UP) Erase Value ? done ! mon : d : h : min 003 : 17 : 22 : 57 Erase Events n=0 y=1 > clear 1 (ENTER) clear - Key and ENTER and - Key and ENTER: Termination of the reset Function. 2 (ENTER) clear www.escalatorparts.cn - Key CLEAR: back to Test - Menu Erase Events ? Please wait! ? 5.2.3 Part – No. - Function Key Sequence M–1–2–3 The Part – No. – Function display the current software version of the EPROM and EEPROM. No. GAA30082AAC 29 – Apr – 94 08:29 It also displays the date and the time of the LCB_II software release. Figure 5-13 :Part – No. – Function - Key GOON / Shift Key GOBACK: Toggle between the displays of the EPROM version and the display that shows the EPROM version and the date / time of the release. goon goon (GOBACK) EE=E47NS9528 No. GAA30082AAC 29 – Apr – 94 08:29 clear - Key CLEAR: back to Test - Menu 1) 3) 2) software version / date / time 1) E 4) EE=E47NS9528 No. GAA30082AAC 29 – Apr – 94 08:29 www.escalatorparts.cn 1)E47NS9528 EEPROM version 2)GAA 30082 AAC EPROM version 3)29 – Apr – 94 4)08:29 date and time of the release 5.2.4 RSL – Test - Function ADR = _ _ _ _ _ _ _ _ _ _ Key Sequence M–1–2–4 The RSL – Test – Function can be used to test the remote Stations. After the address of the Remote Station is entered, - the four Input Pins are monitored and - the four Output pins can be set. Figure 5-13 : RSL / Test - Function Enter the RSL – address 1 2 - Key 1,5: Input Keys of the RSL - address ADR=15 clear clear - Key CLEAR: deletes the last input if you want to correct the number. - Shift Key ENTER: termination of the input operation The current status of the Input – and Output pins of The entered RSL address is displayed. Change address, pin and output www.escalatorparts.cn - ADR=15 IN : off BIT = 1 OUT : off - Key GOON / Shift Key GOBACK: Skip to the next / Previous address. goon goon ADR = 16 IN : off 2 BIT = 1 OUT : off - Shift Key UP / Shift Key DOWN: Skip to the next / Previous bit. 3 ADR = 16 BIT = 2 IN : off OUT : off 1 0 - clear - 1) ADR = 16 IN : off 3) 4) (on = action / off = not active) www.escalatorparts.cn ADR = 16 BIT = 2 IN : off OUT : on Key CLEAR: back to Test - Menu 2) BIT = 2 OUT : on 5.2.5 Selfest - Function Shift Key ON / Shift Key OFF: Toggle of the Output Pin: on / off RSL: Status 1) ADR RSL address(decimal) 2) BIT RSL - pin 3) IN RSL Input Pin Status (Monitor) 4) OUT RSL Output Pin Status Key Sequence M–1–2–5 PR ? EE ? RA ? RS ?_ _ _ _ _ _ Function Selftest can be used - to test the memory of the LCB_II board and - to check the Remote Serial Link. The test will start as soon as the Selftest - Function Is called. Figure 5-14: Selftest - Function PR + EE - RA ? RS ?_ _ _ _ _ PR + EE + RA + RS 16aR0000 RS – Remote Station Test www.escalatorparts.cn The flashing question mark indicates which part of the test is currently active (RA): - PR EPROM - test - EE EEPROM - test - RA RAM-test - RS Remote Serial Link test The single results are displayed as: - (+)for Test successfully finished - ( -)for Test not successfully finished Please notice that for the EE – test a checksum written into the EEPROM is verified .So, the first call of the test with a new EEPROM will result a (-) The RS – test will give some information about single Remote Station. - if they are setup but not available - if they are responding - if they are parity errors RS - test PR + EE + RA + RS 16aR0000 goon goon 16 RSL - address A B available (IO-No. is defined) not available R responding (Hardware is okay) r not responding 000 parity error counter - Key GOON / Shift Key GOBACK : Skip through the list of Remote Station which signals - not available or - not responding or - parity errors. PR + EE + RA + RS 48Ar000 - If there was at least one entry in the list ,the display for Test not successfully finished ( - ) occurs. clear www.escalatorparts.cn - Key CLEAR: back to Test - Menu PR + EE + RA + RS -_ _ _ _ _ _ 5.3 SETUP - FUNCTION Key Sequence SETUP – Menu > Install=1 RSL=2 M–1–3 goon SETUP – Menu > Allowed=3 POS=4 clear SETUP – Menu > 1 Install – Menu > 01 System 000 System new TOP =004> Install – Function SETUP – Menu > RSL - Function 2 6 3 ALLOWED – Menu > 01 Enable at CUDE CUDE P R 00 1100 0000 0 0 Allowed – Function 4 5 to Floor : Display press ENTER ELD - Function SETUP OLD NEW PCS L 00 = 010 > 000 POS - Function to start DCS press ENTER DCS - Function Figure 5-15 : SETUP - Functions In the following all the SETUP – function are explained. The Install , RSL , Allowed , POS and ELD functions are used to set the parameters and masks of the EEPROM whereas the DCS Run function has the task to check if every open door opens the safety chain. There are four different groups of Setup Parameters to define the elevator environMent: - Installation Patameter - RSL – IO Numbers - Allowed Masks - Position Indicator Parameter - ELD - Display The DCS – Function is used to test the well installed Door safety chain after startup and setup phase. www.escalatorparts.cn 5.3.1 Install - Function Key Sequence Short Key M–1-3 Install S4 Function Install is used to set the Installation parameter. The parameters are divided into 8 groups .The Install Menu gives access to each group .(see : 4.2.6) INSTALL – Menu 01 - System > 000 System new TOP =0 0 4 > Figure: 5-16: Install – Function 1) The range of each parameter is defined and controlled By software. The storage operation is disabled if the cabin is moving. (see : document: List of Installation Constants) 3) Element – No. / Group / Name 000 System new TOP =004 > 2) goon goon 1) 000 element – No of group 2) System current group name 3) name of current Install Parameter TOP - Key GOON / Shift Key GOBACK :Skip through the assigned Group of Installation Parameter (System) 001 System new LOBBY =001 > clear www.escalatorparts.cn - Key CLEAR: back to Install - Menu Enter a new parameter 1) 2) Input: Install Parameter 000 System new TOP =004>- - - 1) 004 current value of Install parameter 2) 000 input field for new Parameter - Key 3.2: Input Keys of the new Parameter (32) 3 2 000 TOP clear System new =004 > 032 - Key CLEAR : deletes the last input if you want to correct the number. 000 System new TOP =004 > 003 clear - Shift Key ENTER: Termination to store the Install Parameter into the EEPROM (ENTER) 000 System new TOP =003 > notice : For security reasons the storage operation is disable if the cabin is moving. www.escalatorparts.cn 5.3.2 RSL – Function Key Sequence Short Key IO I AD P AD P >- - - - - - - - - - - - - - - - Figure 5-17 : RSL – Function M–1–3–2 RSL S5 The arrow IS pointing to the input field of the IO Number. After you entered the IO-Number the curRent RSL information stored in the EEPROM is displayed.Now you can change the RSL – Addr.and the RSL – Plug. The Invert Bit can not be changed . It is set by software For RSL – Adr. 0-4 it is always set to zero. (see document : List of Inputs and Outputs) Enter the IO - Number - Key 2.2.2: Input Keys of the desired IO – Number (222) 2 2 2 IO I AD P AD P > 0222_ _ _ _ _ _ _ _ _ _ clear clear (ENTER) - Key CLEAR: deletes the last input if you want to correct the number. - Shift Key ENTER: Termination of the IO – number input: IO I AD P AD P 0022=0 57 2> The current information store in the EEPROM is displayed: IO : IO – Number AD: Remote Station – Addr. I : Invert Bit P: Remote Station – Plug Note: Once a IO – Number is defined, it is stored in the system. clear www.escalatorparts.cn - Key CLEAR : clear the display to enter a new IOnumber. IO I AD P AD P >_____________ Change the IO - Number - Key GOON / Shift Key GOBACK: Skip to the next / previous IO – Number. goon goon (GOBACK) 2 - Shift Key UP / Shift Key DOWN: Skip to the next / previous IO Number with defined RSL – Addr. and RSL – Pin/Plug. 3 Enter new RSL - Parameter 1) 2) Input: RSL - Parameter IO I AD P AD P 0032 = 0 04 2>_ _ _ _ _ 0 9 3 clear clear (ENTER) www.escalatorparts.cn 1) AD new RSL – Addr. 2) P new RSL – Pin/Plug - Key 0,9,3:Input Keys of RS – Addr.: 04 and RS – Pin : 2 IO I AD P AD P 0032 = 0 57 2 > 04 2 - Key CLEAR : deletes the last input if you want to correct the number. - Shift Key ENTER : Termination of the RSL – Parameter input operation. 5.3.3 Allowed – Function ALLOWED – Menu 01 Enable Key Sequence M–1–3-3 Function Allowed is used to set the Floor Table Masks. The masks are divided into 3 groups: - Enable - Cut_Call - Card Rd. The Allowed Menu gives access to each group. > at CUDE CUDE P R 00 1100 0000 0 0 Figure 5.18: Allowed - Function Enable Display 1) 2) 3) 4) Enable Display 5) 1) at at CUDE CUDE P R front door Enable Mask 00 1100 0000 0 0 and The Enable Masks (CUDE) allows the Elevator to run to a certain level depending On the regarding call. If the Parking Bit is set to 1, parking at a Certain level is not allowed (Group applic.) The Reduced Landing No. indicates that The above floor is a Short – or Medium loading. The velocity (profile) is a function of the number (1,2,3 or 4,5,6). Cut_Call Display www.escalatorparts.cn level number (0) 2) CUDE 3) CUDE -C -U -D -E real door Enable Mask, with: - Car Call - Up Hall Call - Down Hall Call - Emergency Hospital Call ( 1 = allowed / 0 = not allowed ) 4) P Park Bit: ( 1 = allowed / 0 = not allowed) 5) R Reduced landing No.: - Short Run (1,2,3 = profile) - Medium Run (4,5,6 = profile) 1) 2) 3) Cut_Call Display 4) at CUDE CUDE Op 00 0100 0000 0 The Cut_Call Masks (CUDE) are used to suppress the Enable Mask if a Cut_Call signal (CHCS…) occurs. The indication Parking with door open defines the door state during parking. 1) at 2) CUDE level number (0) front door Cut_Call Masks and 3) CUDE rear door Cut_Call Masks, with: -C - Car Call -U - Up Hall Call -D - Down Hall Call -E - Emergency Hospital Call (1 = allowed / 0 = not allowed) 4) OP Parking with door open 0 = both doors closed 1 = only front door closed 2 = only rear door open 3 = both doors open Card_Rd ,display 1) 2) 3) 4) at CUDE CUDE Sb 00 0010 0000 0 The Card_Rd Masks (CUDE) are used to Reach certain floors with magnetic card (Card Reader Operation). The indication Special door open button Defines the operation of the Special Door Open Button. www.escalatorparts.cn Card_Rd Display 1) at level number (0) 2) CUDE front door Card_Rd Masks and 3) CUDE rear door Card_Rd Masks, with -C -U -D -E 4) Sb - Car Call - Up Hall Call - Down Hall Call - Emergency Hospital Call (1 = allowed / 0 = not allowed) Special door open button 0 = both SDOB disabled 1 = only front SDOB enabled 2 = only rear SDOB enabled 3 = both SDOB enabled Change the level goon - Key GOON / Shift Key GOBACK: Skip to the next level number goon (GOBACK) clear at CUDE CUDE P R 01 1110 0000 0 0 - Key CLEAR: Back to Allowed - Menu - Key 0,1,0…:Input Keys of All the number (10) of the current row. Enter new Allowed – Parameter 0 1 0 at CUDE CUDE P R 01 > 010 _ _ _ _ _ _ _ (…) clear clear (ENTER) www.escalatorparts.cn - Key CLEAR: deletes the last input if you want to correct The number - Shift Key ENTER: Termination of the Allowed – Parameter input Operation. OTIS 2000 - Openings and Dummy Doors For the controller types MCS120 / MCS220 (OTIS2000) Openings and Dummy Doors are defined as follows: - The Openings are determined by Software regarding to the level Arrangement done with Function AllowedEnable and the following Rule: at CUDE CUDE P R 00 1100 0000 0 0 Count the Front – and Rear Doors for each Level beginning at Front / Level 0 - A Dummy Door is an option to define the same Level Arrangement for every elevator in Group applications. - Shift Key UP: <toggle key> Display of the determined Openings. 2 F : 00 R: - - 2 0 0 (…) clear (ENTER) www.escalatorparts.cn at Front Door of Level 0 : Opening 0 at Rear Door of Level 0: no Opening - Key 2,0,0…:Input Keys of all the number (10)of the current row.(level 1) 2000 is the Code for a Dummy Door. - Shift Key ENTER: Termination of the AllowedParameter input operation. The new determined Openings are displayed. F : 01 R: 02 at F:00 R : -- P R 00 1100 0000 0 0 at F : 0 1 R : - - P 01 > 200 at F : 01 R : 02 01 2000 1110 at Front Door of Level 1 : Opening 1 at Rear Door of Level 1 : Opening 2 R PR 0 0 5.3.4 POS - FUNCTION Pos . Ind. at : L 00 new > = 10 M–1–3-4 Key Sequence Function POS is used to set the digits of the Position Indicator. For each level a left (L) and a right (R) digit is provided to indicate the floor. The range of each digit is defined in the table below. Figure 5-19 POS - Function 3) Pos . Ind At : L 00 = 10 > 1) goon goon (GOBACK) new 2) 4) Input : POS digits 1) L left digit R right digit 2) 00 level number (00) 3) 10 current value of Pos.Ind.digit (10 = blank) 4) new input field for new value. - Key GOON / Shift Key GOBACK : Skip first to the next / previous digit and then to the next / previous level. Pos . Ind . new At : R 00 =00 > Pos . Ind . At : L 00 =10 > clear www.escalatorparts.cn - Key CLEAR: back to Setup - Menu new ENTER a new digit - Key 1,5: Input Keys of the desired digit ( 15 = E ) (see: Reference List below) 1 5 Pos . Ind . at : R 00 =10 new >15 - Key CLEAR: deletes the last input if you want to correct the number. clear - Shift Key ENTER: Termination of the input operation clear The current information Stored in the EEPROM Is displayed: (ENTER) Pos . Ind . at : R 00 =15 > new Reference List value symbol value symbol value 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 (blank) A B* C D* E F G* H I* 20 21 22 23 24 25 26 27 28 29 ( * for 16 – segment only! ) www.escalatorparts.cn symbol J* K* L M* N* O P Q* R* S value 30 31 32 33 34 35 36 37 38 39 symbol T* U V* W* X* Y* Z* 5.3.5 Door Check Sequence Key Sequence M–1–3-5 The Door Check Sequence (DCS) – Function is a safety feature for OTIS 2000 Controllers MCS120 and MCS220 (M), It insures that all hoist way door contacts are installed correctly and will Open the safety chain. Until the Door Check Sequence is finished successfully it is only possible to move the car in inspection mode. Normal runs are disabled. Calibrating an LSVF without speed encoder before DCS For LSVF (-W) without speed encoder it is necessary to calibrate the drive package in Inspection an Normal mode before the DCS can be done. In an Installation with LSVF or LSVF – W without Advanced Door Opening and without Relieving the following display appears: Allow Normal = 0 Start DCS = 1 0 1 www.escalatorparts.cn - Key 0: - Key 1: From now on 5 normal runs are allowed to calibrate the drive package Start the DCS immediately. Direction - 00 DW : clsd ] [ ] [ open front door U D Position - 00 DW :clsd ] [ ] [ open front door - 00 DW :clsd ] [ ] [ open front door - 00 DW :clsd ] [ ] [open front door 00 ** www.escalatorparts.cn stop / direction not defined car is moving in UP direction car is moving in DOWN direction Description actual level (level 0) level position not defined DW status Description DW: clsd DW active (switch closed, door closed) dw:opnd DW passive (switch opened, door open) Door status Description ][][ DCS action - 00 DW :clsd ] [ ] [ open front door Description open front door check DW input close front door open rear door check DW input close rear door up to next level front / rear door status: ] [ for Closed [ ] for Open < > for Opening >< for Closing ** for door state not defined Description (listed are the current actions of the automatic DCS – run) If a failure occurred the error is displayed in the 2nd row. The 1st row shows the status including The level number where the error was detected: - 01 DW : opnd ] [ ] [ Front Door Error Error message Description Front Door Error Rear Door Error aborted by ENTER Door opening err DW not closed Position error Door Closing Err (listed are the possible error message of the automatic DCS – run) After successful completion of the DCS the success message is displayed DCS successful Press GOON > (as reminder what has to be done next) Check PES GTC . . . Press GOON > (to leave DCS run) goon goon 1 to start normal press GOON (GOBACK) LCB_II - Menu System = 1 Tools = 2 www.escalatorparts.cn >_ 5.3.6 ELD - Function Key Sequence M–1–3-6 The ELD – Function is used to define the “Customer Message” of the OTIS 2000 - ELD For each floor the Customer Message can be displayed (Floor Display) modified (Edit Display and Default Display) or store into EEPROM (Store Display). Block diagram 1) 2) 3) 00 < FLOOR ALL < ELD BASEMENT clear < > Send to ELD enter clear 4) 00 5) Floor Display 1) 00 level number <GOON,GOBACK> 2) ALL Edit – Mode: <UP, DOWN> ALL:all characters available A-Z: only A-Z 0-9: only 0-9 &/): only&(),- / : <> SPE:only A A A C /E HEX: all characters available Using hex input mov: move the string to the left of the right current: Customer Message: BASEMENT Edit Display 4) T selected character <GOOM,GOBACK> 5) T selected string position<UP,DOWN> T< ALL ELD BASEMENT ? enter enter clear enter Store Display on 00 confirm the storage operation with Key <ENTER> write E2 P? BASEMENT 6) 7) 8) 00 00 < ELDdef > ENG LOBBY www.escalatorparts.cn Defaut Display No. of Default Message <GOON,GOBACK> 7)ENG Select Language ENG english GER german ITA italian 8) selected Default Message (see Reference Table below) 6)00 Floor Display: Select Floor and Edit Mode 00 < Floor All < ELD BASEMENT - Key 0-9 ,GOON ,GOBACK: Selects, decreases or increases the Floor Number (level) - The current Customer Message which is stored in the EEPROM will be display on the Service Tool (line two). 0 9 goon goon 01 < Floor All < ELD _ _ _ _ FLOOR 1_ _ _ 9 (GOBACK) 2 3 (UP) (DOWN) - Key UP/DOWN: Selects the Edit-Mode ,which will be used in Edit – Display. 01 < Floor A-Z < ELD FLOOR 1 clear 2 - Key ENTER: Transition to Edit Display (ENTER) 01 1 < clear www.escalatorparts.cn - Key Clear: Back to Setup – Menu. Modified Message will be sent to the ELD – Module. A – Z < ELD FLOOR ? Edit Display : Modify Customer Message 00 T< All ELD BASEMENT 2 3 (UP) (DOWN) - Key UP / DOWN: The second row display the current Customer Message. Use Key UP / Down to select the position of current string you want to modify. The position is marked with a bliking “?” The selected Character is displayed in the Edit – Field of row one. 00 N < All ELD BASEME?T goon goon - Key GOON / GOBACK: Skips through the character set using the selected step width. (Key - No) (GOBACK) 00 0 < All ELD BASEME?T 1 9 clear - Key 1 – 9: Skips through the character set using the selected step width. (Key-No.) -Key ENTER: Tramsition to Store Display to store the string into EEPROM. (ENTER) 1 (ON) clear www.escalatorparts.cn -Key ON: Transition to Default Display To use predefined Customer Messages. (see Reference Table below) 00 00 < ELDdef > ENG LOBBY -Key CLEAR: Back to Floor Display e,g. to change the Edit – Mode. The current Message will be buffered. Edit Modes HEX and mov HEX Display 1) 2) HEX Display 1) Y 2) 59 0 0 Y < 59 HEX ELD LOBB? 3) Edit - Field HEX - Field Display the HEX - Value of the selected character selected Character (Y < - > ?) 3) clear - Key UP / DOWN: Selects the string position you want to modify. clear (UP) (DOWN) - Key GOON / GOBACK: Skips through the character set of Edit – Mode ALL to select the new character. goon goon (GOBACK) 0 - Key 0…F: Input of 2 digits Hex – Code in HEX – Field to define the new character (see Reference Table below). F … Mov Display 0 0 GOON > LOBBY ELD F F F (GOBACK) www.escalatorparts.cn - Key GOON / GOBACK : The display message will be shifted to the right/left. It‟s easy way the center the message on the ELD. Default Display: Use of predefined messages 00 00 < ELDdef > ENG LOBBY 2 3 F F (UP) (DOWN) goon goon 2 (GOBACK) 0 9 - Key GOON / GOBACK: Skips through the Default Message List. (see Reference Table below) - Key 0 – 9 Two digits input to select the Default Message by entering the List – No. (see Reference Table below) - Key ENTER: Transition back to Edit Display. The desired Default Message will be buffered. clear on clear (OFF) www.escalatorparts.cn - Key UP / DOWN: Selects the language of the Default Message (ENG,GER,ITA) - Key CLEAR, OFF: Back to Edit Display without buffering the changes. Reference Tables for ELD - Function DEFAULT MASSAGES NO. ENG 0 LOBBY 1 BASEMENT 2 PENTHOUSE 3 FLOOR 4 RECEPTION 5 EXIT 6 GARAGE 7 SECRETARY 8 RESTAURANT 9 CAFETERIA 10 GARAGE 11 POOL 12 SAUNA 13 DOCTOR 14 0 123 456 789 15 : . () <> / - , & ‟ 16 ABCD EFGH IJKL 17 MNOP QRST UVWXYZ Ä Á Å Ç Ø ö /E 18 19 empty string GER ERDGESCHOSS KELLER DACHTERRASSE ETAGE EMPFANG AUSGANG TIEFGARAGE SEKRETARANT RESTAURANT KAFFESTUBE PARKHAUS SCHWIMMHALLE SAUNA ARZT 0 123 456 789 : . () <> / - , & ‟ ABCD EFGH IJKL MNOP QRST UVWXYZ Ä Á Å Ç Ø ö /E ITA TERRANO SOTTERRANEO ATTICO PLANO RICEZIONE USCITA POSTEGGIO SEGRETERIA RISTORANTE CAFFETERIA POSTEGGIO PISCINA SAUNA DOTTORE 0 123 456 789 : . () <> / - , & ‟ ABCD EFGH IJKL MNOP QRST UVWXYZ Ä Á Å Ç Ø ö /E HEX – CODE TABLE ASCII HEX ASCII HEX ASCII Blank & ( ) , . / : < > 20 26 28 29 2C 2D 2E 2F 2A 3C 3E 0 1 2 3 4 5 6 7 8 9 30 31 32 33 34 35 36 37 38 39 A B C D E F G H I J K L M www.escalatorparts.cn HEX ASCII 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D N O P Q R S T U V W X Y Z HEX ASCII 4E 4F 50 51 52 53 54 55 56 57 58 59 5A Ä Á Å Ç A-E Ø ö HEX 80 81 82 83 84 85 86 87 M-2 5.4 TOOLS – Function Key Sequence TOOLS – Menu > 01 Search IO TOOLS – Menu > 02 erase IO goon TOOLS – Menu > 01 Setup IO F TOOLS – Menu > 09 Opr. Memory clear 1…9 Search : IO Adr: 00 / Pin: 0 ? Erase – IO : Pass n=0 y=1 / Enter 1: Search – IO 2: ERASE – IO ? Setup Inst ? n=0 y=1 / Enter 7: Setup – INST A-00 IDL ST ] [ ] [ 00000 9: Opr.Memory Figure 5-12 :TOOLS - Functions In the following all the TOOLS – functions are explained. It is a list of 4 functions that makes the installation, debugging and maintenance of the elevator easier. www.escalatorparts.cn clear 5.4.1 Search – IO - Function Search – IO _ Adr: 00 / Pin: 0 ? Figure 5-22: Search – IO - Function M–2–1 Key Sequence Function Search – IO displays which IO – numbers Are assigned to a certain RSL – address / pin. After input of Adr.and pin and termination with ENTER the Search Run begins and will be indicated with the change of : (?) - > (!). The find of an IO – number interrupts the Search Run and the number is displayed. ENTER will continue the Search Run Enter Adr. And Pin - Key 1,5,3: Input Keys of RSL – Adr.and Pin 1 5 Search – IO ? Adr: 15 / Pin: 3 3 clear clear 3 (ENTER) - Key CLEAR: deletes the last input for correction - Shift Key ENTER: Termi- nation of the input opera- tion and start of the Search Run. Possible Results: (a) no IO – number found Search – IO no match ! www.escalatorparts.cn Search - IO Adr : 15 / Pin; 3 ! (b) first IO – number found Search – IO ? >15 3 < ro: 0676_ The first IO – number is found : Search – IO ? > 15 3< IO : 0676 clear IO :0676 Now you can continue the Search Run with ENTER It is also possible to edit the Adr./Pin display > 15 3 < Search – IO ! > 15 3 < IO: 0676 - Shift Key ENTER: Continue the Search Run. (ENTER) If you want to edit the Pin Number ,press: clear 4 clear - Key CLEAR ,to delete the last input - Key 4, to enter the new pin Search – IO > 15 4 < IO: 0676 ? - Shift Key ENTER , to continue the Search Run (ENTER) Search – IO ! > 15 4 < IO: 0676 If there is no more IOnumber defined,the no more match! – display comes up clear www.escalatorparts.cn - Key CLEAR: back to TOOLS - Menu Search – IO !_ no more match ! 5.4.2 Erase – IO - Function Erase IO Part ? n=0 y=1 / Enter_ Figure 5 – 23: Erase IO_Part M–2–2 Function Erase IO_Part can be used to set the IOPart of the EEPROM to default. You have to confirm twice to start the function, beCause after the run all the previous definitions are lost! (see document: List of inputs and Outputs) - Key CLEAR: back to TOOLS - Menu clear 0 Key Sequence clear clear - Key 0 and Shift Key ENTER: back to TOOLS - Menu (ENTER) 1 clear - Key 1 and Shift Key ENTER First Confirmation Earse IO Part n=0 y=2 / ENTER ? (ENTER) clear 0 - Key 0 and Shift Key ENTER : back to TOOLS - Menu (ENTER) clear 2 (ENTER) - Key 2 and Shift Key ENTER Second Confirmation to start the function. During the run the displayed counter is counting down to zero. www.escalatorparts.cn Erase IO Part Please Wait : 107 ! 5.4.3 Setup install - Function Setup Install n=0 y=1 / Enter Figure 5 – 24: Erase Install ? Key Sequence M–2–3 Function Erase Install can be used to set the Install Part of the EEPROM to default. You have to confirm twice to start the function.because after the run all the previous definitions are lost! (see document: List of Installation Constants) - Key CLEAR: back to TOOLS - Menu clear clear 0 - Key 0 and Shift Key ENTER First Confirmation (ENTER) clear 1 - Key 1 and Shift Key ENTER First Confirmation (ENTER) clear 0 Setup Install N=0 y=2 / Enter ? - Key 0 and Shift Key ENTER : back to TOOLS – Menu (ENTER) clear 2 (ENTER) - Key 2 and Shift Key ENTER Second Confirmation to Start the function. During the run the displayed Counter is counting down to zero. www.escalatorparts.cn Setup Install Please Wait : ! 12 5.4.4 Operate Memory M–2-9 Key Sequence Function Operate Memory can be used to monitor and Change the memory. (You can change only the RAM.) To enter hexadecimal number the Hex Keys are available The Short Keys (see chapter: 4.3) are not active. (!) Please notice that the Operate Memory function is provided only for software debugging. LCB_II System = 1 - Menu Tools = 2 7 8 9 4 5 6 No. M 7 8 9 F 4 5 6 S 3 2 1 0 goon clear 0 1 2 3 Shift - Keys OFF ON UP DOWN 4 - DISP IN 5 - SEL OUT 67 - DISP STATE 8 - ENT CALL 9 - TEST ENTER GOBACK Shift Key Figure 5 – 25: Hex Keys www.escalatorparts.cn HEX Keys - A B C D E F The first row of Figure 5 – 26 display the Software Status (see:5.1.1) The second row displays the input field for the desired Memory Address. After the address is entered is entered. the next two bytes of memory are displayed. A – 00 IDL ST ] [ ] [00000 Please notice that PLM – words are stored in the order: LOW – byte / HIGH - byte Figure 5-26 : Opr.Memory Enter the memory address 7 2 - Key 2.Shift Key 5:Input Keys of the desired Memory Address (2D Hex) A – 00 IDL ST ] [ ] [ 0002D - Key CLEAR:deletes the last input if you want to correct the number. clear - Shift Key ENTER: Termination of the input operation. clear A – 00 IDL ST ] [ ] [ 0 0 0 2 D : 2143 (ENTER) Operate Memory : Monitor A – 00 IDL ST ] [ ] [ 0 0 0 2 D : 2143 1) low byte of word at address 0002D www.escalatorparts.cn 2) high byte of word at address 0002E 1) 0 0 0 2 D desired memory address (2D Hex) 2) 2 1 4 3 memory contents of address 2D and 2E Change the memory address goon goon (GOBACK) 2 (UP) www.escalatorparts.cn 3 (DOWN) - Key GOON / Shift Key GOBACK: Skip to the next / previous Memory address (last four digits). - Shift Key UP / Shift Key DOWN: Skip to the next / previous address in steps of 10000h (first digit). A – 00 IDL ST ] [ ] [ 0 0 0 2 E :_4 3 BA A – 00 IDL ST ] [ ] [ 1 0 0 2 E : 5B7D Change the memory contents - Shift Key SELECT: „>‟ indicates the input field „------‟ are placeholders for the up to four digits of the new byte resp.two bytes. 5 (SELECT) A – 00 IDL ST ] [ ] [ 0 0 0 2 D : ABCD> - - - - Depending on how many digits are entered the first byte or both or both bytes are stored. The first up to two digits form the first byte and the next up to row digits the second byte. Examples of changing the old contents ABCD: Keys goon goon (ENTER) New memory contents ENTER ---- ABCD 1.ENTER -1-- 01CD 1.2 ENTER 12-- 12CD 1.2.3 ENTER 12-3 1203 1.2.3.4 ENTER 1234 1234 - Key GOON / Shift Key GOBACK: Aborts changing of memory contents. A – 00 IDL ST ] [ ] [ 0 0 0 2 D : ABCD (GOBACK) clear Display - Key ENTER: Storing the new byte resp.two bytes. A short appearing “+” behind the entered byte resp. two bytes acknowledges the successful storing failure (e.g.memory address is out of RAM area). A – 00 IDL ST ] [ ] [ 0 0 0 2 D : ABCD>12 – 3+ A – 00 IDL ST ] [ ] [ 0 0 0 2 D : 1203 天津市东海电梯公 司 -电梯配件中心 TEL:022-27057755 FAX:022-27057766 www.escalatorparts.cn