Uploaded by drelagrinn6777937

671211307-TPL63

advertisement
0
2
1
4
3
5
6
7
8
9
WUPE001D 20.07.1999
DURMAZLAR MAKINE SANAYI A.S.
DURMA
:
Design
TPL93/63
671211307
:
:
:
:
TPL93/63 1250x20 PUNCH PRESS
SINUMERIK 840DSL-SINAMICS S120
X-Y1-Y2-T-C1-C2-U
SIEMENS/SINAMICS S120
HL
:
CE
:
SICK OPTEX
LEVENT UDGU
KEREM KOC
Responsible for Project :
:
18/03/2010
27/12/2010
Created on :
Processed on :
Tel : +90 224 2191800
Fax : +90 224 2427580
Web : www.durmazlar.com.tr
VERSION: TPL93_HL_XPSL_10_03
:
Customer
Plant Designation :
Machine Serial Nr.:
Machine Type
Control Unit Type
Axis
Servo System
Hydraulic Block Type
Norm
Front Protection
ORGANIZE SAN.BÖL.
75.YIL BULVARI
BURSA/TURKEY
Elec.Cabinent
:
1925x1100x440mm
Power Supply
Control Voltage
Power Consumption
Mains Supply Cable
Mains Fuses
:
:
:
:
:
3X400/50HZ
24VDC
35Kw
3X10+6mm²
70A
PLC : TPL93_XPSL_VPLC_10_12_01
NC : TPL93_XPSL_VNC_10_12_01
HMI : TPL93_XPSL_VHMI_10_01_03
DP : TPL93_XPSL_VDP_10_12_01
by :
Last Page No
No. of pages
KKOC
:
:
49
48
2
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
TPL93 840 DSL
DURMA
durmazlar
1956
P.
1
49 P.
0
2
1
4
3
5
6
7
8
9
1
Title page / cover sheet
TP9 840DSL
06/05/2010
KKOC
2
Table of contents
Table of contents
06/05/2010
KKOC
3
Table of contents
Table of contents
06/05/2010
KKOC
4
Panel layout
ELECTRICAL CABINET& CLAMP FOOT PEDAL& TOOL CHANGE PANEL
05/05/2010
KKOC
5
Schematic multi-line
HYD.PUMP MOTOR & ELECTRICAL CABINET FANS
06/05/2010
KKOC
6
Schematic multi-line
COMMAND VOLTAGE INPUTS
06/05/2010
KKOC
7
Schematic multi-line
PUMP MOTOR STAR-DELTA CIRCUIT
06/05/2010
KKOC
8
Schematic multi-line
EMERGENCY STOP CIRCUIT
06/05/2010
KKOC
9
Schematic multi-line
S120 DRIVERS & MOTORS
06/05/2010
KKOC
10
Schematic multi-line
S120 DRIVERS & MOTORS
06/05/2010
KKOC
11
Schematic multi-line
S120 DRIVERS & MOTORS
06/05/2010
KKOC
12
Schematic multi-line
I/Q CARD CIRCUIT
06/05/2010
KKOC
14
Schematic multi-line
PROFIBUS and ETHERNET CABLE CIRCUIT
06/05/2010
KKOC
15
Schematic multi-line
U AXIS CONTROL AND PCU 3L MODUL CIRCUITS
06/05/2010
KKOC
16
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
17
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
18
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
19
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
20
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
21
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
22
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
23
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
24
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
25
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
26
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
27
Schematic multi-line
PNU.VALVE CIRCUIT
06/05/2010
KKOC
28
Schematic multi-line
PNU.VALVE CIRCUIT
06/05/2010
KKOC
29
Schematic multi-line
PCU50
06/05/2010
KKOC
30
Schematic multi-line
MACHINE CONTROL PANEL
06/05/2010
KKOC
31
Schematic multi-line
PLC OUTPUTS
19/04/2010
KKOC
32
Schematic multi-line
PHOTOCELL CIRCUIT
06/05/2010
KKOC
33
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
34
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
35
Schematic multi-line
PLC INPUTS
06/05/2010
KKOC
36
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
37
Schematic multi-line
PLC OUTPUTS
06/05/2010
KKOC
38
Schematic multi-line
LIGHT BRRIER SETTING PLAN
08/04/2010
KKOC
39
Terminal diagram
X0
40
Terminal diagram
X1
1
3
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
Table of contents
DURMA
durmazlar
1956
P.
2
49 P.
0
2
1
4
3
41
Terminal diagram
X2
42
Terminal diagram
X2
43
Terminal diagram
X2
44
Terminal diagram
X2
45
Terminal diagram
X2
46
Parts list
47
Parts list
48
Parts list
49
Parts list
5
6
7
8
9
2
4
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
Table of contents
DURMA
durmazlar
1956
P.
3
49 P.
0
2
1
4P1
4
3
1100
5
6
7
8
440
9
12A5
WIRE CHANNEL
16A1
20A1
19A1
19S8
8K5
7K3
8K4
26A1
7K2
15A1
5Q2
7K1
WIRE CHANNEL
7KX
KLEMENS
8A1 5A2
KLEMENS
7KY1
6A6
7KY2
6A4
KLEMENS
WIRE CHANNEL
5Q1
5M7
32R7
11A5
11A1
10A6
10A4
WIRE CHANNEL
32R6
9Q1
5Q3
6Q4
6F11
5F6
6F3
6F2
6F5
6F6
6F12
6F8
6F9
6F7
6F1
6F10
10A2
20S4
9A6
20S6
9A4
25L2
WIRE CHANNEL
9A1
8S3
25L5
6A1
WIRE CHANNEL
20S8
25L3 25L6
WIRE CHANNEL
TERMINAL BLOCK
25L1 25L4
1925
WIRE CHANNEL
5Q1
5M8
WIRE CHANNEL
TERMINAL
BLOCK
10R3 10R5 10R8
6J
5J
19J
J
5Q1
:Main switch
8S2,8S3 :Emergency Stop Button
20S8 :Tool Change Safety Button
20S4 :Turret Turn Ccw-Cw
20S6 :Turret Index On-Off
25L1 :Fault (General)
25L2 :Fault (Index)
25L3 :Turrets Indexed
25L4
3
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
6T8
:Turrets Free
TPL93/63
671211307
19S7 :Clamp Control Foot Pedal
Foot Pedal Of Ref.Cyl.
25L5 :Turret Cw
25l6 :Turret Ccw
5J
:Lights Barrier
J
:Main Control Unit
19J
:Clamp Control Foot Pedal
And Ref.Cyl.Foot Pedal
6J
:Loading System
ELECTRICAL CABINET&
CLAMP FOOT PEDAL&
TOOL CHANGE PANEL
DURMA
19S7
CLAMP
FOOT
PEDAL
durmazlar
1956
FOOT
PEDAL OF
REF.CYL.
5
P.
4
49 P.
0
2
1
4
3
1L1
1L2
1L3
1L2
I>
N
L1
T2
T3
80A
L1
L2
L3
L2
I>
4T2
6T3
2L1
2L2
2L3
9
L1 / 6.0
L2 / 6.0
L3 / 6.0
N / 6.0
PE / 6.0
1,5mm²
5F6
I>
2T1
8
1L1
5L3
C2A
1
6mm²
N
1
1
-X2 1
L3
5A2
5Q1
7
2
16.3
20-25A
1L3
1,5mm²
T1
6
5Q3
1L1
1L1
3L2
5
-X2 N
5L6
3
2L1
1
2L2
3
2L3
2L1
5
1
7K1
7.1
3
5
7K3
2
4
3L1
3L2
7.2
6
1L1
3L2
5L3
2T1
4T2
6T3
2L3
1
3
5
2
4
6
7K2
2
2V2
3L3
2L2
4
6
2W2 2U2
7.1
2V2
220V 8W
TURRET LIGHTING
LAMP
2W2 2U2
5Q2
16.3
10-16A
1U1
1V1
-X2 1
-X2 N -X2 PE
1
1W1
-X2 N -X2 PE
2
J
J
1
-X1 U1 V1 W1 PE
-X2 1
2
1
V2 W2 U2
1
N
N
W1 7x2,5mm² cable
U1
V1
W1
PE
L
M
3~
5M3
7,5Kw/11Kw
U2
V2
5M6
W2
N
M
1~
L
N
L
M 5M8
1~
5M7
PE
N
M
1~
PE
PE
10mm²
-X0 L1
L1
L2
L3
N
PE
L2
L3
N
PE
Uk 16mm²
400V/50HZ SUPPLY
PHASE SEQUENCE
RELAY
PUMP MOTOR
POWER SUPPLY
220V-AC
CONTROL PANEL
FAN-LUFTER
ELECTRIC PANEL
FAN-LUFTER
4
6
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
HYD.PUMP MOTOR &
ELECTRICAL CABINET FANS
DURMA
durmazlar
1956
P.
5
49 P.
0
2
1
4
3
5
5.9 / L1
5.9 / L2
5.9 / L3
5.9 / N
5.9 / PE
6
7
8
9
L1 / 7.0
L2 / 7.0
L3 / 7.0
1L1
2L1
1L3
1
N
2
1
1L3
5
1,5mm²
I>
I>
I>
2
4
6
N
6L1
6L2
1L1
N
2
1.1-1.6A
3
10L3
3
PE / 7.0
1L3
6Q4
4
6F1
2P 4A
1L2
4
6F11
C4A
6A1
IN 230VAC
OUT 24VDC 10A
L1
1
2P 4A
1
2P 4A
3
PE
6L3
7L3
202
+5/24VDC/ 9.0
N
L3
L
N
N
6F12
-
PE
+
7
X2:6 / 9.0
132
10A
133
133 2
0
24
137 24V
138
2
6F9
2A
0VDC/J:7/ 29.0
1
134
-X2 7 -X2 PE
1
139
2,5mm²
6F2
-X2 5
24VDC/J:8/ 29.0
220V
2,5mm²
131
2,5mm²
2,5mm²
0
400VA
400/220-24V
130
5
-X2 N
8L3
6T8
6A6
2,5mm²
201
4
N
IN 230VAC
OUT 24VDC 10A
-
10A
L2
6A4 3
+
200
1
8L1
IN 380VAC
OUT 24VDC 20A
6F10
-
3
400
6F3
N
2
6F8
2
L
1L3
B1 / 7.0
+4/24VDC/ 26.0
B2 / 7.0
1,5mm²
C4A
6F5
133 2
1
-X2 4
4
24VDC
+1/24VDC/ 8.0
2,5mm²
6A
6F6
133 2
1
136
6M3
6F7
1331
C°
N
OIL COOLER
MOTOR AUTO
CONTROL
+2/24VDC/ 15.0
1,5mm²
C6A
2
4A
????
-X2 25
25
L
0V DC
M
1~
X2:5 / 7.3
2,5mm²
PE
7
6J
220V AC
OIL COOLER MOTOR
5
7
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
+3/X2:25/ 16.0
1mm²
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
COMMAND VOLTAGE INPUTS
DURMA
durmazlar
1956
P.
6
49 P.
0
2
1
4
3
5
6
7
8
9
6.9 / L1
6.9 / L2
6.9 / L3
L1 / 9.0
L2 / 9.0
L3 / 9.0
6.9 / PE
PE / 9.0
1L1
1L2
1L3
OPTION
OPTION
1
3
5
2
4
6
26K4
26.4
1L1
1L2
1L1
3L2
5L3
7Q8
16A1
12.6
11L1
28
31
34
22R1
22R3
22.1
27
28
29
22.3
29
33
35
35
34
140
139
30
22.2
31
I>
11L3
141
139
141
143
01
.1
10L3
1L1
3L2
5L3
I>
I>
I>
16.3
1.0 - 1.6A
I>
I>
2T1 4T2 6T3
6U1
6V1
6W1
2T1 4T2 6T3
5U1
5V1
5W1
-X1 U6 V6 W6
-X1 U5 V5 W5
1
3
5
2
4
6
26K3
I>
26.3
4U1
4V1
4W1
145
42
144
A1
145
7KY1
A1
7K2
145
7KY2
A1
A1
7KX
A1
137
A2
3RT1025-1AB00
3RH1921-1CA01
1
2 5.4
01
02 .1
3
4 5.4
5
6 5.4
A2
5
137
OV AC
3RT1025-1AB00
3RH1921-1FA31
1
2 5.5
3
4 5.5
5
6 5.5
13
14 16.2
41
42 .2
7M6
0.37 kW
A2
OV DC
6.6 / X2:5
3RH1140-1BB40
3RH1911-1FA04
13
14 18.1
51
52 10.2
61
62 10.2
71
72 10.3
81
82 10.3
-X1 U4 V4 W4
145
7K3
A2
137
5L3
7Q7
U1
A2
10L2
6T3
7K2
02
142
A1
I>
4T2
41
7K3
140
3L2
7Q6
143
READY/ 9.5
.2
I>
2T1
32
1mm²
3RT1025-1AB00
3RT1926-1CB00
1
2 5.3
3
4 5.3
5
6 5.3
11L2
32
16.3
1.0 - 1.6A
6.9 / B2
11L3
16.3
4.5 - 6.3A
10L1
24V AC
7K1
11L2
11L1
22R2
1L1
139
6.9 / B1
1L3
A2
5
5
3RH1140-1BB40
3RH1911-1FA04
13
14 18.1
51
52 10.5
61
62 10.5
71
72 10.6
81
82 10.6
3RH1140-1BB40
3RH1911-1FA04
51
52 10.8
61
62 10.8
71
72 10.8
81
82 10.9
V1
W1
M
3~
U1
7M7
0.37 kW
V1
W1
U1
M
3~
PE
PE
PE
W1
M
3~
7M8
2,2Kw
PE
V1
PE
X2:5 / 8.0
CONVEYOR
MOTOR
VACUUM
MOTOR
6
8
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PUMP MOTOR STAR-DELTA
CIRCUIT
DURMA
durmazlar
1956
P.
7
49 P.
0
2
1
4
3
5
6
7
8
9
6.6 /+1/24VDC
+1/24VDC/ 9.0
24VDC
24VDC
147
1mm²
149
11
147
21
5A2
149
14
4
24
6
J
1mm²
J
4
1
6
1
2
2
3
5
1mm²
8S2
J
J
3
11
-X2 11
TCP
20.3
25.0
4
3
6J
6J
4
5
16
33
-X2 16
1
1
.5
12
146
2
1
17
148
4
4
8A1
A1
8K5
.6
34
34
2
-X2 17
-X2 12
4
33
8K4
8S3
2
4
Y11
Y12
A2
Y33
5
Y21
Y22
Y34
103
101
13
23
14
24
104
105
104
105
6J
6J
6J
6J
5
6
21
8K4
.5
22
102
21
A1
8K5
.6
7.9 / X2:5
8K4
22
101
A1
8K5
A2
A2
5
5
3RH1131-1BB40
3RT1916-1BB00
13
14 9.5
21
22 .2
33
34 .8
43
44 16.1
3RH1131-1BB40
3RT1916-1BB00
13
14 9.5
21
22 .2
33
34 .8
43
44 16.1
0VDC
0VDC
X2:5 / 9.0
7
9
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
EMERGENCY STOP CIRCUIT
DURMA
durmazlar
1956
P.
8
49 P.
0
2
1
4
3
5
6
7
8
9
8.9 /+1/24VDC
+1/24VDC/ 10.0
8.9 / X2:5
X2:5 / 10.0
6.2 /+5/24VDC
6.2 / X2:6
1L2
1
3
1L3
ACTIVE INTERFACE
MODULE
36KW
3AC 380-480V 60A 50/60HZ
5
PROFIBUS CABLE
.
.
.
.
CF
40-63A
I>
I>
2
4
6
5
107
4
5
X24
110
202
201
+
M
X201
PUNCHSTART/ 15.2
X202
5
106
READY/ 7.4
5
5
600VDC
X126
9Q1
I>
15.5
1
2
3
4
4
4
+
0V M
M
profibus
1L1
5
X21
NC
NC
EP +24V
EP M
24VDC
+24V +
15A1
14
5
5
145
108
5
X126
12A5
13
READY FOR /
CYCLE START
6SL3130-7TE23-6AA3
X200
X122
X120
X130
10mm²
109
108
110
1
2
3
4
5
6
7
8
9
10
11
12
9A6
14
8.6
X105
X102
+
0V M
M
X124
+24V +
8K4
8.5
4
13
8K5
201
X101
FAN OFF
X132
202
3
4
6FC5371-0AA10-0AA1
1
2
3
4
5
6
7
8
9
10
11
12
X104
107
T1 1
T2 2
X121
PE / 12.0
9A4
106
6SL3100-0BE23-6AB0
X103
9A1
X100
7.9 / L1
7.9 / L2
7.9 / L3
7.9 / PE
RDY
T0
T1
T2
T3
RDY
DC LINK
RUN
STOP
SU/PF
SF
DP1
9L1
9L2
DP2
9L3
OPT
BOP
SIM/NCK
....
....
PLC
ACTIVE LINE
MODULE
36KW
RESET
840Dsl NCU 710.2
-X1
10mm²
L1
L2
L3
U2
V2
W2
-X1
PE
U1
PE
10mm²
V1 W1
-X1
9L3
9L1
3W2
3W2
9L2
3V2
3U2
PE
10mm²
3V2
3U2
8
10
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
S120 DRIVERS & MOTORS
DURMA
durmazlar
1956
P.
9
49 P.
0
2
1
4
3
5
6
7
8
9
9.9 /+1/24VDC
+1/24VDC/ 11.0
9.9 / X2:5
X2:5 / 11.0
10A2
10A4
6SL3120-1TE23-0AA3
+Temp
-Temp
EP +24V
EP M
4
X21
+Temp
-Temp
EP +24V
EP M
4
600VDC
600VDC
600VDC
RDY
RDY
DC LINK
DC LINK
DC LINK
SINGLE MOTOR
MODULE
SINGLE MOTOR
MODULE
SINGLE MOTOR
MODULE
INPUT-PC600V
OUTPUT-3AC 400V 30A
INPUT-PC600V
OUTPUT-3AC 400V 30A
INPUT-PC600V
OUTPUT-3AC 400V 18A
W1 GND
PE
U1
V1
W1 GND
PE
10mm²
51
U1
10M3
V1
W1
M
3~
AXIS-Y
52
U
V1
W1 GND
PE
10mm²
61
71
81
51
61
71
7KY1
U1
5
X202
24VDC
V1
4
X201
24VDC
RDY
9
1
2
3
4
X200
X201
X202
5
X200
X200
X201
X202
5
1
2
3
4
24VDC
U1
62
72
V
82
10mm²
81
51
61
71
81
52
62
72
82
7KY2
7.3
U1
10M4
W 10R3
3x1,1Ω
PE
V1
W1
M
3~
AXIS-Y2
52
U
62
72
V
82
7KX
7.4
W 10R5
3x1,1Ω
U1
10M8
PE
V1
W1
M
3~
AXIS-X
U
V
7.5
W 10R8
3x2,1Ω
PE
11
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
6SL3120-1TE21-8AA3
X21
1
2
3
4
+Temp
-Temp
EP +24V
EP M
10A6
6SL3120-1TE23-0AA3
X21
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
S120 DRIVERS & MOTORS
DURMA
durmazlar
1956
P.
10
49 P.
0
2
1
4
3
5
6
7
8
10.9 /+1/24VDC
9
+1/24VDC/ 12.0
10.9 / X2:5
X2:5 / 12.0
11A1
11A5
6SL3120-2TE15-0AA3
6SL3120-1TE15-0AA3
X21
+Temp
-Temp
EP +24V
EP M
1
2
3
4
+Temp
-Temp
EP +24V
EP M
1
2
3
4
X21
+Temp
-Temp
EP +24V
EP M
4
5
1
2
3
4
4
5
4
X202
5
X200
X200
X201
X201
X202
X203
X22
24VDC
24VDC
600VDC
600VDC
RDY
RDY
DC LINK
DC LINK
DOUBLE MOTOR
MODULE
SINGLE MOTOR
MODULE
INPUT-PC600V
OUTPUT-3AC 400V 5A/5A
INPUT-PC600V
OUTPUT-3AC 400V 5A
X1
U1
V1
X2
W1 GND PE
U1
V1
W1 GND PE
10mm²
U1
V1
W1
M
11M1
3~
U1
W1 GND PE
10mm²
U1
V1
10mm²
W1
U1
M
11M2
3~
PE
AXIS-T
V1
V1
W1
M
11M5
3~
PE
PE
AXIS-C1
AXIS-C2
10
12
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
S120 DRIVERS & MOTORS
DURMA
durmazlar
1956
P.
11
49 P.
0
2
1
4
3
5
6
7
8
9
11.9 /+1/24VDC
11.9 / X2:5
9.1 / PE
+1/24VDC/ 32.0
X2:5 / 15.0
PE / 15.0
12A5
PROFIBUS
6FC5611-0CA01-0AA0
I/Q MODUL
12A5
4
5
24V
0V
5
PE
4
5
4
5
4
16A1
-
7.0
16.0
17.0
18.0
22.0
23.0
27.1
28.0
28.5
+
-X111
DURMA
IQ2416
4
19A1
19.0
20.0
21.0
24.0
25.0
4
+
DURMA
I24
-X222
OPTION
26A1
26.0
31.0
33.0
26.0
31.0
20A1
24.0
24.3
24.5
27.0
32.1
28.3
28.8
DURMA
IQ2416
DURMA QB1
1-COM 2-NO 3-NC
-X333
- +
-
-
-
5 5 5
-
-
+
+
4
4
5 4
-
4 4 4
11
14
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
I/Q CARD CIRCUIT
DURMA
durmazlar
1956
P.
12
49 P.
0
2
1
4
3
5
6
7
8
9
15A1
PCU 3L
PROFIBUS
X5
A2
B2
SWITCH ON
A1
B1
SWITCH OFF
A1
B1
SWITCH ON
A1
B1
A2
B2
ETHERNET2
X201
29A4
PCU50 840D
X100
X20
X200
X201
X200
X201
X201
X200
X200
X200
X201
X201
X200
X101
30A1
MCP 483
DP
PROFIBUS
X120
PROFIBUS
X21
A2
B2
9A4
9A6
10A2
10A4
10A6
11A1
11A5
12A5
I/Q CARD
12
15
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PROFIBUS and ETHERNET CABLE CIRCUIT
DURMA
durmazlar
1956
P.
14
49 P.
15A1
X1
20
111
1
2
112
5
113
114
115
116
6
7
8
9
/ 9.6
X2:5 / 16.0
PE / 29.0
9A4
PROFIBUS CABLE
READY FOR
CYCLE START
PTE 2 / 21.1
NO ERRORCONDıTıON / 19.5
5
PTE 1 / 19.6
-X2 20
4
RUN / 25.7
FORM TOOLPUNCH START / 24.3
24VDC
0VDC
PUNCHSTART / 9.6
6.6 /+2/24VDC
12.9 / X2:5
12.9 / PE
3
TOOL CHANGE MODE POSITION/ 24.2
2
1
MARKING START / 25.8
0
Brown
White
Green
WRS232
9Pin
4x0,22
HL
PCU 3L-PG
CONNECTOR
-X2 19
117
19
SW1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
X6
2
3
2
PCU 3L
3
4
Com
Gnd
High
pressure
PE
ON
1
U AXIS
POSITIONING UNIT
GND
OFF
4
RS 232
READY
NOERR
INPOS2
INPOS1
ENABLE
RUN
1
X5
OUT-X1
UDSEL1
SELCYC2
SELCYC1
START2
START1
IN-X1
24V
5
2
3
5
24V DC SUPPLY
7
Pink
2
Orange
6
Yellow
-X2 23
-X2 22
WHV1
1
Yellow
22
5
Blue
23
9
X3
Violet
3
Green
5
2
Green
136
12
Brown
red
11
Brown
10
White
Grey
X2
X4
1
2
5
136
3
4
5
7
8
W15A5
8x0,22
White
3x1
6
6
X4--B
1
3
5
7
X4--C
1
3
5
7
W15M7 8x0,50mm²
1-WHITE
3-BROWN
9
5-BLUE
7-RED
10
1
>X2
1
2
3
4
6
7
2
0V
SUPPLY
ENCA+
ENCA- ENCB+
ENCB-
HV1
BERGER LOHR
Uch:40V
In:2.1A
R:1Ω
1
>X1
AIE 1
15A5
AIA 2
BIE 3
BIA 4
1
MAGNETIC
SENSÖR
ENCODER
LMIX
ELGO ELEKTRIK
15M7
HIGH-LOW
PRESSURE VALVE
14
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
LMS
SENSÖR
U AXIS CONTROL AND
PCU 3L MODUL CIRCUITS
STEPPER MOTOR
16
DURMA
durmazlar
1956
P.
15
49 P.
0
2
1
15.9 / X2:5
6.6 /+3/X2:25
4
3
5
6
7
8
9
0VDC
0VDC
X2:5 / 17.0
24VDC
24VDC
+3/X2:25/ 17.0
-X2 25
25
OPTION
13
OPTION
7Q8
7.8
14
BOX-3
13
25
25
7.7
43
7K2
8.5
7.1
44
118
14
120
2x1
14
155
13
8K4
13
16S4
13
13
16S5
14
7Q6
7.6
-X5 25
W16S7
7Q7
1
16S6
14
13
16S7
P
2
1
16S8
P
14
2
14
-X2 13
W16S8
3x0,50
154
-X2 13
95
118
5Q2
5.3
43
13
96
8K5
16S7.1
8.6
44
BOX-3
-X5 30
14
121
119
W16S7.1
2x1
-X2 26
13
-X2 27
-X2 28
-X2 29
-X2 30
5Q3
5.3
5
16A1
119
1
12.6
120
14
26
27
28
29
30
122
3
4
5
6
7
8
9
I32.0
I32.1
I32.2
I32.3
I32.4
I32.5
I32.6
10
I32.7
PLC INPUTS/PLC EINGANG
0V
EMERGENCY
STOP O.K
HYD. PUMP
MOTOR IS
WORKING
MOTOR
CURRENT
PROTECTION
SHEET CRASH
SWITCH1
SHEET CRASH
SWITCH2
CENTRAL
LUBRICATION
OIL LEVEL
TURRET
COVER
SWITCH
MAIN AIR PRESSURE
O.K.
15
17
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC INPUTS
DURMA
durmazlar
1956
P.
16
49 P.
0
2
1
4
3
5
6
7
8
OVDC
16.9 / X2:5
24VDC
16.9 /+3/X2:25
-X2 5
OVDC
X2:5 / 18.0
24VDC
+3/X2:25/ 18.0
BOX-1
-X2 5
-X2 25
9
-X2 25
-X3 25
-X2 25
OPTION
OPTION
BOX-2
-X4 5
-X4 25
5
1
25
17S3
1
17S8
2
17S1
-
1
2
+
17S2
-
12.6
32.7
5
3
32R7
9
32.7
9
2x1
17S4
BOX-1
4
2
-X3 33
BOX-2
16A1
1
+
4
32R6
W17S5
3x0,50
1
5
3
W17S3
2
1
17S5
P
-X4 31
32
-X2 31
-X2 32
-X2 33
-X2 34
-X2 35
-X2 36
-X2 37
-X2 38
31
32
33
34
35
36
37
38
11
12
13
14
15
16
17
18
I33.0
I33.1
I33.2
I33.3
I33.4
I33.5
I33.6
I33.7
PLC INPUTS/PLC EINGANG
CH1
MULTITOOL FIX
SWITCH
MULTITOOL FREE
SWITCH
CLAMP AIR
PRESSURE O.K.
(CLOSE)
VACUUM VALVE
SWITCH
TOOL LUBRICATION
TANK OIL LEVEL
(LOW)
CH2
LIGHT BARRIER
O.K.
SHEET LUBRICATION
TANK OIL LEVEL
(LOW)
16
18
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC INPUTS
DURMA
durmazlar
1956
P.
17
49 P.
0
2
1
17.9 / X2:5
17.9 /+3/X2:25
4
3
5
6
7
8
0VDC
24VDC
9
0VDC
X2:5 / 19.0
24VDC
+3/X2:25/ 19.0
-X2 5
-X2 25
BOX-1
BOX-2
-X3 25
-X4 25
-X4 25
-X4 25
-X2 5
-X2 25
-X4 25
25
BU
13
18S2
7KY2
7.4
-
REXROTH
0830-100-629
14
BN
BN
+
BN
18S3
18S4
REXROTH
0830100381
BK
BU
BN
18S5
REXROTH
0830100380
BU
REXROTH
0830100380
BN
18S6
BU
REXROTH
0830100380
18S8
18S7
BU
-
BN
REXROTH
0830100380
BU
123
+
-
+
BALLUF
BES 516346-H2-Y
NO
123
BOX-1
13
7KY1
7.3
BOX-2
-X3 40
-X4 41
-X4 42
-X4 43
-X4 44
-X2 40
-X2 41
-X2 42
-X2 43
-X2 44
14
124
-X2 39
124
16A1
19
12.6
I34.0
-X2 45
39
40
41
42
43
44
45
20
21
22
23
24
25
26
I34.1
I34.2
I34.3
I34.4
I34.5
I34.6
I34.7
PLC INPUTS/PLC EINGANG
SIMODRIVE
READY
17
WORKCHUTTE
CLOSED
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
REFERENCE 1
CYL.(UP-DOWN)
Change Date
UPPER TURRET
INDEXED
TPL93/63
671211307
UPPER TURRET
FREE
LOWER TURRET
INDEXED
LOWER TURRET
FREE
CLAMPS POSITION
CONTROL SWITCH
19
PLC INPUTS
DURMA
durmazlar
1956
P.
18
49 P.
0
2
1
4
3
5
6
7
8
0VDC
0VDC
18.9 / X2:5
18.9 /+3/X2:25
9
X2:5 / 20.0
+3/X2:25/ 20.0
24VDC
-X2 5
-X2 25
-X2 25
BOX-2
-X4 5
-X4 25
BU
19S1
-X4 5
-X4 25
BN
-
BU
+
BALLUF
BES M12MIPSC40B-BV03
19S2
BK
-X4 5
-X4 25
BU
+
19S3
BALLUF
BES M12MIPSC40B-BV03
BALLUF
BES M12MIPSC40B-BV03
BK
-
BN
BU
+
19S4
BK
BALLUF
BES M12MIPSC40B-BV03
-
PE
25
19J
BN
-
25
-X4 5
-X4 25
BN
1
19S8
13
+
19S7
20.3
BK
19J
14
24
2
-X2 24
W19S7
BOX-2
-X4 46
-X4 47
-X4 48
-X4 49
-X2 46
-X2 47
-X2 48
-X2 49
15.5
15.4
NO ERRORCONDıTıON
PTE 1
15A1
X1:11
15A1
X1:9
117
115
20.3
4x1
24
125
5
46
19A1
12.8
1
47
48
49
125
3
4
5
6
7
8
9
I35.0
I35.1
I35.2
I35.3
I35.4
I35.5
I35.6
126
10
I35.7
PLC INPUTS/PLC EINGANG
UPPER
AUTO-INDEX
GEARED
18
UPPER
AUTO-INDEX
FREE
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
LOWER
AUTO-INDEX
GEARED
TPL93/63
671211307
LOWER
AUTO-INDEX
FREE
15A1
NO ERROR
CONDITION
15A1
PTE 1
CLAMP CONTROL
FOOT PEDAL
PUNCHING ROD
ON TOOL
20
PLC INPUTS
DURMA
durmazlar
1956
P.
19
49 P.
0
2
1
4
3
5
6
7
8
0VDC
19.8 / X2:5
9
X2:5 / 21.0
19.8 /+3/X2:25
+3/X2:25/ 21.0
WTCP
24VDC
.4
19x0,75
TCP
BOX-2
-X4 5
-X4 25
8.1
25.0
-X4 5
-X4 25
25
19J
BU
20S1
-
BN
BU
+
BALLUF
BES M12MIPSC40B-BV03
20S2
BK
-
BN
13
+
3
19S7
19.7
BALLUF
BES M12MIPSC40B-BV03
3
BK
3
20S4
19J
14
3
3
3
20S6
4
4
20S8
4
4
4
4
W19S7
19.7
4x1
-X4 50
WTCP
127
-X4 51
.4
19x0,75
BOX-2
-X2 50
19A1
12.8
-X2 51
50
51
11
12
I36.0
-X2 52
127
13
I36.1
I36.2
-X2 53
-X2 54
-X2 55
-X2 56
52
53
54
55
56
14
15
16
17
18
I36.3
I36.4
I36.5
I36.6
I36.7
PLC INPUTS/PLC EINGANG
PUNCHING ROD
OUTSIDE
PUNCHING ROD
INSIDE
19
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
FOOT PEDAL
OF
REF.CYL.
Change Date
TPL93/63
671211307
CW
CCW
TURRET TURN
INDEX ON
INDEX OFF
TURRET
MANUEL CONTROL
ENABLE
TURRET
21
PLC INPUTS
DURMA
durmazlar
1956
P.
20
49 P.
0
2
1
20.9 / X2:5
20.9 /+3/X2:25
4
3
5
6
7
8
9
OVDC
OVDC
X2:5 / 25.0
24VDC
+3/X2:25/
-X2 5
-X2 25
-X2 25
-X2 25
BOX-2
-X4 25
-X4 5
BU
1
21S2
15.4
PTE 2
21S3
P
-
BALLUF
BOS 5KPS-IX10-01
3
BN
+
BU
21S4
BK
PE
25
-
BALLUF
BOS 5KPS-IX10-01
15A1
X1:10
BOX-1
-X3 5
-X3 25
BN
+
BU
21S5
21S7
BU
+
BALLUF
BES 516324-E4-C-03
21S6
BK
-X2 25
-X3 5
-X3 25
BN
-
-X2 25
BALLUF
BES 516324-E4-C-03
-X3 59
-
BN
BN
+
-X2 21
BK
BN
21S8
REXROTH
0830100-380
21S9
REXROTH
0830100-380
BU
BU
-X3 60
BOX-1
OPTIONAL
-X2 57
116
19A1
19
12.8
I37.0
-X2 58
-X2 59
-X2 60
57
58
59
60
20
21
22
23
I37.1
I37.2
I37.3
I37.4
-X2 61
129
24
I37.5
-X2 62
61
62
25
26
I37.6
I37.7
PLC INPUTS/PLC EINGANG
15A1
PTE 2
HL BLOCK
PRESSURE CONTROL
SWITCH
TOOL CONTROL
PHOTOCELL
CLAMP1
SHEET
CONTROL
20
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
CLAMP2
SHEET
CONTROL
OPTIONAL
SHEET REF.
CONTROL
SWITCH
CLAMP
CLUTCH
FREE
CLAMP
CLUTCH
INDEXED
22
PLC INPUTS
DURMA
durmazlar
1956
P.
21
49 P.
0
2
1
4
3
5
6
7
8
9
16A1
12.6
PLC OUTPUTS/PLC AUSGANG
Q40.1
Q40.0
A1
Q40.2
A1
22R1
Q40.3
A1
22R2
A1
22R3
A2
Q40.4
A1
22R4
A2
Q40.5
A1
22R5
A2
Q40.6
A1
22R6
A2
A2
Q40.7
A1
22R7
A2
22R8
A2
A2
-
29
27
32
30
28 7.0
MAIN
STAR
34 7.1
DELTA
---------5M3 HYD.PUMP. MOTOR---------
21
38
36
37 28.5
CLAMP 1
RELEASE
41
39
40 28.6
CLAMP 2
RELEASE
44
42
43 27.2
MAIN AIR
CONTROL
47
45
46 27.3
WORKCHUTE
CLOSED-OPEN
50
48
49 27.3
PUNCHING ROD
INSIDE
23
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
35
33
31 7.2
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
22
49 P.
0
2
1
4
3
5
6
7
8
9
16A1
12.6
PLC OUTPUTS/PLC AUSGANG
Q41.1
Q41.0
A1
Q41.2
A1
23R1
A1
23R2
A2
Q41.3
A1
23R3
A2
Q41.4
A1
23R4
A2
Q41.5
Q41.6
A1
23R5
A1
23R6
A2
A2
Q41.7
A1
23R7
A2
23R8
A2
A2
-
53
51
56
54
52 27.4
REFERENCE
CYL.
55 27.5
PUNCHING ROD
OUTSIDE
59
57
58 27.6
TURRETS
INDEXED
62
60
61 27.7
TURRETS
FREE
65
63
64 28.0
AUTO-INDEX
GEARED
22
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
68
66
67 28.1
AUTO-INDEX
FREE
71
69
70 28.2
REPOSITION
CYLINDER
DOWN
74
72
73 28.7
CLAMP 3
RELEASE
24
PLC OUTPUTS
DURMA
durmazlar
1956
P.
23
49 P.
0
2
1
4
3
5
6
7
8
9
PLC OUTPUTS/PLC AUSGANG
19A1
12.8
Q42.0
Q42.1
31
20A1
Q42.2
32
33
113
111
34
24R1
Q42.5
35
24R4
FORM TOOL
PUNCH START
15.3
15.2
15A1
X1:5
24R6
PLC OUTPUTS
PLC AUSGANG
X2:63
15A1
TOOL CHANGE
MODE POSITION
15A1
FORM TOOL
PUNCH START
TOOL
LUBRICATION
PHOTOCELL
RESTART
23
Date
03/03/2010
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
A1
24R8
A2
A2
PLC OUTPUTS
PLC AUSGANG
32.4
REL-MR- 24DC/21HC
11
12
10 32.1
Design
24R7
A2
38
A1
15A1
X1:2
REL-MR- 24DC/21HC
2
3
1 28.4
CLAMP
CONTROL
CLOSE
38
37
A1
A2
TOOL CHANGE
MODE POSITION
Q42.7
37
36
12.8
QB1
A1
A2
PLC OUTPUTS
PLC AUSGANG
Q42.6
36
20A1
34
12.8
QB1
A1
Q42.4
63
20A1
31
12.8
QB1
Q42.3
Sing
Change Date
TPL93/63
671211307
REL-MR- 24DC/21HC
17
18
16 28.8
REL-MR- 24DC/21HC
20
21
19 27.1
REL-MR- 24DC/21HC
23
24
22 28.3
MULTITOOL
FIXED
H-L
HYDRAULIC
BY-PASS
VALVE RELAY
CLAMP
CLUTCH
25
PLC OUTPUTS
DURMA
durmazlar
1956
P.
24
49 P.
0
2
1
4
3
5
6
7
19A1
8
9
PLC OUTPUTS/PLC AUSGANG
12.8
Q43.0
Q43.1
8.1
20.3
Q43.4
Q43.5
Q43.6
Q43.7
40
41
42
43
44
45
46
64
65
66
67
68
69
114
112
-X2 65
x1
-X2 66
x1
25L1
red
Q43.3
39
-X2 64
TCP
Q43.2
x1
25L2
x2
red
-X2 67
25L3
x2
green
x1
25L4
x2
-X2 68
green
x2
green
MARKING START
15.3
15.3
15A1
X1:6-7
15A1
X1:3
-X2 69
x1
25L5
RUN
x1
25L6
x2
green
x2
26.0
21.9 / X2:5
X2:5
0VDC
FAULT
(GENERAL)
FAULT
(INDEX)
TURRETS
INDEXED
TURRETS
FREE
CW
CCW
TURRET TURN DIRECTION
15A1 RUN
ENABLE
MARKING
START
24
26
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
25
49 P.
0
2
1
4
3
5
6
7
8
9
OPTION
26A1
12.6
PLC OUTPUTS/PLC AUSGANG
Q44.1
Q44.0
A1
Q44.2
A1
22R1
Q44.3
A1
22R2
A1
22R3
A2
A1
22R4
A2
Q44.5
Q44.4
A1
22R5
A2
Q44.6
A1
22R6
A2
22R7
A2
Q44.7
A2
A1
22R8
A2
A2
-
26A1
12.6
28
31
22R1
.1
28
34
22R2
27
29
.2
29
134
31
90
30
32
34
91
33
35
151
36
38
38
37
134
43
22R5
.4
35
134
40
22R4
.3
32
134
37
22R3
.5
40
152
22R6
39
41
41
134
.6
43
92
42
44
44
134
92
6.6 /+4/24VDC
+4/24VDC/ 27.0
-X2 90
BOX-1
-X2 91
-X2 92
151
-X3 90
152
A1
PV18
PV17
A1
26K3
PE
26K4
PV19
A2
A2
5
5
-X2 5
-X2 5
PE
-X2 94
PV20
PE
PE
BOX-1
-X2 5
-X2 5
-X2 5
-X2 5
25.9 / X2:5
X2:5 / 27.0
29
27
32
30
28 .1
3RH1140-1BB40
3RH1911-1FA04
351
2 7.8
333
.3
4347.9
31 .2
5
CLAMP 4
RELEASE
VACUUM
VALVE
6 7.9
VACUUM
MOTOR
3RH1140-1BB40
3RH1911-1FA04
381
2 7.7
363
.4
4377.7
5
41
39
40 .5
44
42
43 .6
6 7.7
CONVEYOR
MOTOR
SHEET
LUBRICATION
CENTRAL
LUBRICATION
25
27
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
26
49 P.
0
2
1
20A1
4
3
5
6
7
8
9
16A1
12.8
QB1
12.6
43
19
24R7
24.7
21
46
22R6
21
19
134
49
22R7
20
22.6
42
20
42
43
70
44
44
134
22.7
45
45
46
71
52
22R8
47
47
134
22.8
48
48
49
72
55
23R1
50
50
134
23.1
51
51
52
73
58
23R2
53
53
134
23.2
54
54
55
74
61
23R3
56
56
134
23R4
23.3
57
57
58
75
59
59
134
23.4
60
60
61
76
62
62
134
77
26.9 /+4/24VDC
+4/24VDC/ 28.0
-X2 71
-X2 72
-X2 73
-X2 74
-X2 75
-X2 76
-X2 77
72
73
74
75
76
77
BOX-3
-X5 71
-X2 70
x1
x1
PV1
x1
PV2
x2
x2
-X2 PE
x1
x1
PV3
x1
PV4
x2
-X2 PE
x1
PV5
x2
-X2 PE
x1
PV6
x2
-X2 PE
PV7
x2
-X2 PE
x2
-X2 PE
-X2 PE
HV2
x2
BOX-3
-X5 5
-X2 5
5
5
5
5
5
5
-X2 5
0VDC
0VDC
26.9 / X2:5
X2:5 / 28.0
HL BLOCK
PRESSURE CONTROL
VALVE
MAIN AIR
VALVE
WORKCHUTE
OPEN-CLOSE
VALVE
PUNCHING ROD
INSIDE VALVE
REFERENCE 1
CYLINDER
VALVE(UP)
PUNCHING ROD
OUTER
VALVE
TURRETS
INDEXED
VALVE
TURRETS
FREE
VALVE
26
28
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PNU.VALVE CIRCUIT
DURMA
durmazlar
1956
P.
27
49 P.
0
2
1
16A1
20A1
DURMA IO-2416
1-NC 2-COM 3-NO
12.6
64
67
70
23R6
63
63
64
65
65
134
66
66
67
78
68
69
69
70
134
79
71
71
1
134
80
24
24
22
23
24.1
23
134
3
81
2
1
2
40
134
36
36
37
82
38
38
134
83
16
23R8
22.5
39
39
40
DURMA QB1
1-COM 2-NO 3-NC
73
22R5
22.4
9
12.8
22R4
3
8
20A1
37
24R1
24.8
7
DURMA IO-2416
1-NC 2-COM 3-NO
12.6
24R8
23.7
68
6
16A1
22
23R7
23.6
5
DURMA QB1
1-COM 2-NO 3-NC
12.8
23R5
23.5
4
3
41
41
134
24R6
23.8
72
72
73
84
74
24.6
74
134
18
18
16
85
17
17
134
86
27.9 /+4/24VDC
+4/24VDC/ 31.0
-X2 78
-X2 79
-X2 80
-X2 81
-X2 82
BOX-3
-X2 83
-X2 84
-X2 85
-X2 86
BOX-1
-X5 78
79
PV8
80
PV9
81
PV10
-X2 PE
-X3 82
PV11
PE
BOX-3
83
PV12
PE
84
PV13
PE
85
PV14
PE
-X5 86
PV15
PE
PV16
PE
PE
BOX-1
BOX-3
-X5 5
5
5
5
-X2 5
-X3 5
PE
BOX-3
5
5
5
-X5 5
-X2 5
27.9 / X2:5
X2:5 / 32.0
AUTO-INDEX
GEARED
VALVE
AUTO-INDEX
FREE
VALVE
REPOSITION
CYLINDER
DOWN
VALVE
27
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
CLAMP
CLUTCH
VALVE
CLAMP
CONTROL
VALVE
CLAMP 1
RELEASE
VALVE
CLAMP 2
RELEASE
VALVE
CLAMP 3
RELEASE
VALVE
MULTITOOL
FIXED
VALVE
29
TPL93/63
671211307
PNU.VALVE CIRCUIT
DURMA
durmazlar
1956
P.
28
49 P.
0
2
1
6.7 /24VDC/J:8
6.7 /0VDC/J:7
15.9 / PE
4
3
24VDC
0VDC
5
6
7
8
9
24VDC / 30.0
0V / 30.0
PE / 30.0
132
131
2,5mm²
30A1
30.1
8
7
J
MCP
6FC5303-0AF22-0AA0
J
8
7
M
P
6FC5203-0AF05-0AA0
OPERATOR PANEL FRONT-OP15
P
M
USB
PORT2
Ethernet 2
24V
0V
PE
COM 2
29A4
PCU50.3, 1.5GHz, XP
6FC5210-0DF31-2AA0
USB
PORT0
ETHERNET
ETHERNET CABLE
USB
PORT4
9A4
28
30
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PCU50
DURMA
durmazlar
1956
P.
29
49 P.
0
2
1
4
3
5
6
7
8
9
29A4
PROFIBUS CABLE
PCU 50
6FC5220-0YA31-2AA0
30A1
29.5
1
MACHINE CONTROL PANEL
6FC5303-0AF22-0AA0
2
3
4
5
6
7
8
9
10
ON
X21
PORT 1
OFF
DP ADRESS
EMERGENCY STOP BUTTON
8S2
PE
M24
M
BLUE
P24
1
1
2
2
GREEN
BROWN
RED
P
8x0.50mm²cable
168
29.9 / PE
29.3 / 0V
29.3 / 24VDC
PE /
169
3
J
3
8.2
170
4
J
4
8.2
171
6
J
6
8.3
26.0
5
J
5
8.3
29
31
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
MACHINE CONTROL PANEL
DURMA
durmazlar
1956
P.
30
49 P.
0
2
1
4
3
5
6
7
8
9
26A1
12.6
PLC OUTPUTS/PLC AUSGANG
Q45.1
Q45.0
A1
Q45.2
A1
23R1
Q45.3
A1
23R2
A1
23R3
A2
Q45.4
A1
23R4
A2
Q45.5
A1
23R5
A2
Q45.6
A1
23R6
A2
Q45.7
A1
23R7
A2
23R8
A2
A2
A2
-
26A1
12.6
28
31
23R1
.1
52
27
55
180
37
23R3
.2
29
53
134
34
23R2
30
134
.3
32
56
58
181
33
59
134
40
23R4
.4
35
61
182
134
40
23R5
36
.5
38
62
64
183
39
.6
41
65
134
40
23R6
67
184
40
23R7
39
68
23R8
.7
41
39
70
185
.8
39
73
74
41
71
186
41
187
+4/24VDC/ 28.9
13
14
6J
29
27
15
6J
32
30
28 .1
PUNCH
RESET
16
6J
35
33
31 .2
PUNCH
RUN
6J
34 .3
CLAMPS
ON
38
36
17
18
6J
37 .4
REF. CYCLIN.
DOWN POSITION
41
39
19
6J
40 .5
PUNCH WAIT
ON REF. POINT
41
39
20
6J
40 .6
SYSTEM
RESET
41
39
6J
40 .7
SHEET ON
CLAMP
41
39
40 .8
SHEET TOUCH
REF. CYL.
30
32
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
31
49 P.
0
2
1
4
3
5
6
7
8
9
OPTION
20A1
12.8
QB1
1
5
10
24.4
12
12
32B4
32B2
24R4
-X2 63
11
10
-X2 4
11
1
1
4
3
89
-X2 4
4
5
-X2 5
-X2 4
2
2
4
24.5
24VDC
X2:63
12.9 /+1/24VDC
6
3
-X2 87
4
-X2 88
5
-X2 93
6
-X2 5
4
32R6
.7 12
172
4
32R7
7
7
.7 12
173
FE
FE
2-input 24VDC(voltaj supply)
3-application diagnostic output(ADO)
4-external device monitoring(EDM)
5-OSSD1(output signal switching device 1)
8x0.50mm²cable
8x0.50mm²cable
RECEIVER
1-reset/restart interlock
87
4
4
32A4
Y1
Y2
13
23
14
24
6-OSSD(output signal switching device 2)
7-0VDC(voltage supply)
8-functional earth
UE 10-3 FG
-X2 89
B1
88
x1
B2
93
A2
5
175
32Y4
A1
x2
28.9 / X2:5
176
32R6
A1
32R7
A2
A2
5
5
-X2 5
0VDC
LZX PT 570024
LZX PT 570024
LZX PT78704
LZX PT78704
4
12 .5
4
12 .5
5
9 17.6
5
9 17.7
TOOL LUBRICATION
VALVE
31
33
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PHOTOCELL CIRCUIT
DURMA
durmazlar
1956
P.
32
49 P.
0
2
1
4
3
5
6
7
8
9
21.9 /+3/X2:25
-X2 25
OPTION
9
10
6J
11
6J
1
12
6J
33S8
6J
P
3
-X2 95
188
26A1
1
12.6
189
190
191
95
3
4
5
6
7
8
9
I38.0
I38.1
I38.2
I38.3
I38.4
I38.5
I38.6
10
I38.7
PLC INPUTS/PLC EINGANG
0V
PUNCH
START
PUNCH
STOP
REF. CYC.
ON
CLAMP
ON
CENTRAL
LUBRICATION
PRESSURE OK
32
34
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC INPUTS
DURMA
durmazlar
1956
P.
33
49 P.
0
2
1
4
3
5
6
PLC INPUTS
16A1
7
8
9
PLC GĐRĐŞLER
16A1
PLC PROGRAM
PLC PROGRAM
3
I32.0
EMERGENCY STOP
3
I32.0
ACIL STOP
4
I32.1
HYDRAULIC PUMP MOTOR IS WORKING
4
I32.1
HIDROLIK POMPA MOTORU ÇALIŞIYOR
5
I32.2
MOTOR CURRENT PROTECTION
5
I32.2
AŞIRI AKIM KORUMA DEVREDE
6
I32.3
SHEET CRASH SWITCH1
6
I32.3
SAC KIVRILDI 1
7
I32.4
SHEET CRASH SWITCH2
7
I32.4
SAC KIVRILDI 2
8
I32.5
SPARE
8
I32.5
BOS
9
I32.6
TURRET COVER SWITCH
9
I32.6
TARET KAPAĞI AÇIK
10
I32.7
MAIN AIR PRESSURE O.K
10
I32.7
ANA HAVA BASINCI
11
I33.0
MULTITOOL FIX SWITCH
11
I33.0
MULTITOOL KILITLI
12
I33.1
MULTITOOL FREE SWITCH
12
I33.1
MULTITOOL SERBEST
13
I33.2
CLAMP AIR PRESSURE
13
I33.2
KLEMP HAVA BASINCI
14
I33.3
VACUUM VALVE SWITCH
14
I33.3
HURDA KAPAĞI SENSÖRÜ
15
I33.4
TOOL LUBRICATION TANK OIL LEVEL LOW
15
I33.4
TAKIM YAĞLAMA YAĞ SEVĐYESĐ
16
I33.5
LIGHT BARRIER CHANNEL 1
16
I33.5
IŞIN BARIYERI 1
17
I33.6
LIGHT BARRIER CHANNEL 2
17
I33.6
IŞIN BARIYERI 2
18
I33.7
SHEET LUBRICATION TANK OIL LEVEL LOW
18
I33.7
SAÇ YAĞLAMA YAĞ SEVIYESI
19
I34.0
SIMODRIVE READY
19
I34.0
SIMODRIVE HAZIR
20
I34.1
WORKCHUTTE CLOSED
20
I34.1
PARÇA DÜŞÜRME KAPALI
21
I34.2
REFERENCE CYLENDER(UP-DOWN)
21
I34.2
REFERANS SILINDIRI AŞAĞIDA
22
I34.3
UPPER TURRET INDEXED
22
I34.3
UST TARET KILITLI
23
I34.4
UPPER TURRET FREE
23
I34.4
UST TARET SERBEST
24
I34.5
LOWER TURRET INDEXED
24
I34.5
ALT TARET KILITLI
25
I34.6
LOWER TURRET FREE
25
I34.6
ALT TARET SERBEST
26
I34.7
CLAMPS POSITION CONTROL CONNECTION
26
I34.7
KLEMP POZĐSYON OKUMA
33
35
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC INPUTS
DURMA
durmazlar
1956
P.
34
49 P.
0
2
1
4
3
5
6
PLC INPUTS
19A1
7
8
9
PLC GĐRĐŞLER
PLC PROGRAM
19A1
PLC PROGRAM
3
I35.0
UPPER AUTO-INDEX GEARED
3
I35.0
UST C-INDEX KILITLI
4
I35.1
UPPER AUTO-INDEX FREE
4
I35.1
UST C-INDEX SERBEST
5
I35.2
LOWER AUTO-INDEX GEARED
5
I35.2
ALT C-INDEX KILITLI
6
I35.3
LOWER AUTO-INDEX FREE
6
I35.3
ALT C-INDEX SERBEST
7
I35.4
15A1 NO ERROR CONDITION
7
I35.4
15A1 HATA YOK
8
I35.5
15A1 PTE 1
8
I35.5
15A1 PTE 1
9
I35.6
CLAMP CONTROL FOOT PEDAL
9
I35.6
KLEMP AYAK PEDALI
10
I35.7
PUNCHING ROD ON TOOL
10
I35.7
ÇEKĐÇ TAKIMIN ÜSTÜNDE
11
I36.0
PUNCHING ROD OUTSIDE
11
I36.0
ÇEKĐÇ DIŞARDA
12
I36.1
PUNCHING ROD INSIDE
12
I36.1
ÇEKĐÇ ĐÇERĐDE
13
I36.2
FOOT PEDAL OF REFERENCE CYLINDER
13
I36.2
REFERANS SILINDIRI AYAK PEDALI
14
I36.3
TURRET TURN CW
14
I36.3
MANUEL - TARET SAAT YONUNDE
15
I36.4
TURRET TURN CCW
15
I36.4
MANUEL - TARET SAAT YONUNUN TERSINE
16
I36.5
TURRETS INDEX ON
16
I36.5
MANUEL - TARET KILITLE
17
I36.6
TURRETS INDEX OFF
17
I36.6
MANUEL - TARET SERBEST
18
I36.7
TURRET MANUEL CONTROL ENABLE
18
I36.7
MANUEL KONTROL IZIN
19
I37.0
15A1 PTE 2
19
I37.0
15A1 PTE 2
20
I37.1
HL BLOCK PRESSURE CONTROL SWITCH
20
I37.1
HL BASINC KONTROL
21
I37.2
TOOL CONTROL PHOTOCELL
21
I37.2
TAKIM DIZME KONTROL
22
I37.3
CLAMP1 SHEET CONTROL
22
I37.3
KLEMP1 SAC KONTROL
23
I37.4
CLAMP2 SHEET CONTROL
23
I37.4
KLEMP2 SAC KONTROL
24
I37.5
OPTIONAL SHEET REF.CONTROL SWITCH
24
I37.5
OPSIYON SAC REFERANSDA
25
I37.6
CLAMP CLUTCH FREE
25
I37.6
KLEMP POZISYONLAMA PIMI YUKARIDA
26
I37.7
CLAMP CLUTCH INDEXED
26
I37.7
KLEMP POZĐSYONLAMA PĐMĐ AŞAĞIDA
26A1
26A1
3
I38.0
PUNCH START
3
I38.0
PUNCH START
4
I38.1
PUNCH STOP
4
I38.1
PUNCH STOP
5
I38.2
REFERENCE CYCLINDER UP
5
I38.2
REFERANS SILINDIRI YUKARI
6
I38.3
CLAMP ON
6
I38.3
KLEMP AÇ
34
36
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC INPUTS
DURMA
durmazlar
1956
P.
35
49 P.
0
2
1
4
3
5
6
PLC OUTPUTS
7
8
9
PLC ÇIKIŞLAR
PLC PROGRAM
PLC PROGRAM
Q40.0
HIDROLIK MOTOR ANA
16A1-29
Q40.0
MAIN MOTOR
16A1-29
16A1-32
Q40.1
STAR
16A1-32
Q40.1
HIDROLIK MOTOR YILDIZ
16A1-35
Q40.2
DELTA
16A1-35
Q40.2
HIDROLIK MOTOR UCGEN
16A1-38
Q40.3
CLAMP 1 RELEASE
16A1-38
Q40.3
KLEMP1 SERBEST
16A1-41
Q40.4
CLAMP 2 RELEASE
16A1-41
16A1-44
Q40.5
MAIN AIR CONTROL
16A1-44
Q40.5
ANA HAVA KONTROL
16A1-47
Q40.6
WORKCHUTTE CLOSED-OPEN
16A1-47
Q40.6
PARCA DUSURME AÇIK-KAPALI
16A1-50
Q40.7
PUNCING ROD INSIDE
16A1-50
Q40.7
ÇEKĐÇ ĐÇERĐDE
16A1-53
Q41.0
REFERENCE CYLINDER
16A1-53
Q41.0
REFERANS SILINDIRI
16A1-56
Q41.1
PUNCHING ROD OUTSIDE
16A1-56
Q41.1
ÇEKĐÇ DIŞARIDA
16A1-59
Q41.2
TURRETS INDEXED
16A1-59
Q41.2
TARET KILITLI
16A1-62
Q41.3
TURRETS FREE
16A1-62
Q41.3
TARET SERBEST
16A1-65
Q41.4
AUTO-INDEX GEARED
16A1-65
Q41.4
C-INDEX KILTLI
16A1-68
Q41.5
AUTO-INDEX FREE
16A1-68
Q41.5
C-INDEX SERBEST
16A1-71
Q41.6
REPOSITION CYLINDER DOWN
16A1-71
Q41.6
REPOZISYON SILINDIRI AŞAĞIDA
16A1-74
Q41.7
CLAMP 3 RELEASE
16A1-74
Q41.7
KLEMP3 SERBEST
20A1-2
Q42.0
CLAMP CONTROL ON-OFF
20A1-2
Q42.0
KLMEP AÇ-KAPA
19A1-32
Q42.1
15A1 TOOL CHANGE MODE POSITION
19A1-32
Q42.1
15A1 TOOL CHANGE MODE POSITION
19A1-33
Q42.2
15A1 FORM TOOL PUNCH START
19A1-33
Q42.2
15A1 FORM TOOL PUNCH START
20A1-11
Q42.3
TOOL LUBRICATION
20A1-11
Q42.3
TAKIM YAĞLAMA
19A1-35
Q42.4
PHOTOCELL RESTART
19A1-35
Q42.4
FOTOSEL RESET
20A1-17
Q42.5
MULTITOOL FIXED
20A1-17
Q42.5
MULTITOOL KILITLI
20A1-20
Q42.6
H-L HYDRAULIC BY-PASS VALVE RELAY
20A1-20
Q42.6
H-L HYDRAULIC BY-PASS VALFI
20A1-23
Q42.7
CLAMP CLUTCH
20A1-23
Q42.7
KLEMP POZĐSYONLAMA PIMI
Q40.4
KLEMP2 SERBEST
35
37
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
36
49 P.
0
2
1
4
3
5
6
PLC OUTPUTS
PLC PROGRAM
Q43.0
7
9
PLC ÇIKIŞLAR
GENERAL FAULT LAMP
19A1-39
Q43.0
GENEL HATA LAMBASI
19A1-40
Q43.1
INDEX FAULT LAMP
19A1-40
Q43.1
INDEX HATA LAMBASI
19A1-41
Q43.2
TURRETS INDEXED LAMP
19A1-41
Q43.2
TARET KILITLI LAMBASI
19A1-42
Q43.3
TURRETS FREE LAMP
19A1-42
Q43.3
TARET SERBEST LAMBASI
19A1-43
Q43.4
TURRETS TURN CW LAMP
19A1-43
Q43.4
TARET SAAT YONUNDE DONUYOR
19A1-44
Q43.5
TURRET TURN CCW LAMP
19A1-44
Q43.5
TARET SAAT YONUNUN TERSINE DONUYOR
19A1-45
Q43.6
15A1 RUN-ENABLE
19A1-45
Q43.6
15A1 RUN-ENABLE
19A1-46
Q43.7
MARKING START
19A1-46
Q43.7
MARKING START
26A1-29
Q44.0
CLAMP 4 RELEASE
26A1-29
Q44.0
KLEMP4 SERBEST
26A1-32
Q44.1
VACUUM VALVE
26A1-32
Q44.1
VAKUM VALFI
26A1-35
Q44.2
VACUUM MOTOR
26A1-35
Q44.2
VAKUM MOTORU
26A1-38
Q44.3
CONVEYOR MOTOR
26A1-38
Q44.3
KONVÖR MOTORU
26A1-41
Q44.4
SHEET LUBRICATION
26A1-41
Q44.4
SAC YAĞLAMA
26A1-44
Q44.5
OPTION
26A1-44
Q44.5
OPTION
26A1-47
Q44.6
OPTION
26A1-47
Q44.6
OPTION
26A1-50
Q44.7
OPTION
26A1-50
Q44.7
OPTION
26A1-53
Q45.0
PUNCH RESET
26A1-53
Q45.0
PUNCH RESET
PUNCH ÇALIŞIYOR
19A1-39
8
26A1-56
Q45.1
PUNCH RUN
26A1-56
Q45.1
26A1-59
Q45.2
CLAMP ON
26A1-59
Q45.2
KLEMPLER AÇIK
26A1-62
Q45.3
REF. CYCLIN. DOWN POSITION
26A1-62
Q45.3
REF SILINDIRI AŞAĞIDA
26A1-65
Q45.4
PUNCH WAIT ON REF. POINT
26A1-65
Q45.4
PUNCH REFERANSDA BEKLIYOR
26A1-68
Q45.5
SYSTEM RESET
26A1-68
Q45.5
SISTEM RESET
KLEMPTE SAC VAR
SAC REFERANSDA
26A1-71
Q45.6
SHEET ON CLAMP
26A1-71
Q45.6
26A1-74
Q45.7
SHEET TOUCH REF. CYL.
26A1-74
Q45.7
36
38
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
PLC OUTPUTS
DURMA
durmazlar
1956
P.
37
49 P.
0
2
1
4
3
5
7
8
9
4
5
1
6
BACK/HINTER
LEFT/LINKE
RIGHT/RECHTE
2
3
FRONT/VORDERSEITE
37
39
Date
03/03/2010
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Name
Changes
Surname
Signature
CE
Sing
Change Date
TPL93/63
671211307
LIGHT BRRIER SETTING PLAN
DURMA
durmazlar
1956
P.
38
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
ESSK034E
Strip designation
L1
L2
L3
N
PE
400V/50HZ SUPPLY
=
=
L1
L2
L3
N
PE
Target design.
5Q1
5Q1
5Q1
X2
X1
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X0
Page/
path
L1
L2
L3
N
PE
5.0
5.0
5.1
5.1
5.1
38
40
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X0
DURMA
durmazlar
1956
P.
39
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
W1
ESSK034E
Strip designation
PUMP MOTOR
5M3
PE
PHASE SEQUENCE RELAY
5M3
5M3
7M8
7M7
7M6
5M3
5M3
7M8
7M7
7M6
5M3
5M3
7M8
7M7
7M6
U1
U2
U1
U1
U1
V1
V2
V1
V1
V1
W1
W2
W1
W1
W1
PUMP MOTOR
CONVEYOR MOTOR
=
PUMP MOTOR
=
VACUUM MOTOR
CONVEYOR MOTOR
PUMP MOTOR
=
VACUUM MOTOR
CONVEYOR MOTOR
PE
PE
PE
PE
U1
U2
U4
U5
U6
V1
V2
V4
V5
V6
W1
W2
W4
W5
W6
Target design.
X0
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X1
Page/
path
PE
5Q2
7K2
26K3
7Q7
7Q6
5Q2
7K2
26K3
7Q7
7Q6
5Q2
7K2
26K3
7Q7
7Q6
5.3
9.3
9.4
9.7
5.3
5.5
7.8
7.7
7.6
5.3
5.5
7.9
7.7
7.6
5.3
5.5
7.9
7.7
7.6
2T1
6
2
2T1
2T1
4T2
2
4
4T2
4T2
6T3
4
6
6T3
6T3
39
41
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X1
DURMA
durmazlar
1956
P.
40
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
ESSK034E
Strip designation
5Q1
5F6
PUMP MOTOR
POWER SUPPLY 220V-AC
1
1
1
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
7
11
12
13
13
16
17
1
ELECTRIC PANEL FAN-LUFTER
8A1
32B2
32B2
32R6
7K5X
X4
X4
18S2
X4
21S3
TCP-25L1
OIL COOLER MOTOR
TOOL LUBRICATION VALVE
=
=
OIL COOLER MOTOR
MULTITOOL FIX SWITCH
SIMODRIVE READY
HL BLOCK PRESSURE CONTROL SWITCH
CLAMP 4 RELEASE
A1
2
5
4
A2
5
5
BU
5
BU
x2
=
VACUUM VALVE
CONVEYOR MOTOR
SHEET LUBRICATION
HL BLOCK PRESSURE CONTROL VALVE
MAIN AIR VALVE
AUTO-INDEX GEARED VALVE
X5
X5
32B2
32A4
CLAMP CONTROL VALVE
TOOL LUBRICATION VALVE
=
=
5
5
7
B2
OIL COOLER MOTOR
TCP-8S3
8A1
1
Y11
16S7.1
TCP-8S3
8A1
13
1
Y21
SPARE
=
Target design.
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X2
J
5M8
6F5
1
L
1
20A1
32B4
6A4
16A1
10
2
1
X2
19A1
X4
PV17
PV18
26K3
26K4
PV19
HV2
X5
X5
X3
32Y4
5
1
5
Page/
path
5.6
5.7
5.8
6.6
32.3
32.3
32.4
6.4
17.1
17.2
18.2
19.1
21.3
26.1
26.2
26.3
26.4
26.5
27.1
27.2
28.1
28.5
32.2
32.3
32.4
6.3
8.2
8.2
16.7
16.7
8.3
8.3
A2
A2
x2
5
5
5
x2
32B4
6F3
J
TCP-8S3
16S7
7
1
3
2
14
J
TCP-8S3
5
2
40
42
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X2
DURMA
durmazlar
1956
P.
41
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
W17S5
W16S7.1
Strip designation
WTCP
Cable name
Cable name
WHV1
W16S7
ESSK034E
15A1-X1
15A1-X1
HV1
HV1
8K4
16S7
X4
X4
17S5
18S2
X4
19S8
21S2
21S3
21S7
21S8
21S9
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
LMS SENSÖR
HIGH-LOW PRESSURE VALVE
OIL COOLER MOTOR
SPARE
MULTITOOL FREE SWITCH
VACUUM VALVE SWITCH
WORKCHUTTE CLOSED
UPPER AUTO-INDEX GEARED
CLAMP CONTROL FOOT PEDAL
15A1 PTE 2
HL BLOCK PRESSURE CONTROL SWITCH
CLAMP2 SHEET CONTROL
CLAMP CLUTCH FREE
=
SHEET CRASH SWITCH1
SHEET CRASH SWITCH2
SPARE
=
MAIN AIR PRESSURE O.K.
MULTITOOL FREE SWITCH
CLAMP AIR PRESSURE O.K. (CLOSE)
VACUUM VALVE SWITCH
=
CH1
LIGHT BARRIER O.K.
SHEET LUBRICATION TANK OIL LEVEL (LOW)
WORKCHUTTE CLOSED
REFERENCE 1 CYL.(UP-DOWN)
12
1
1
2
43
13
25
25
1
BN
25
19
20
22
23
25
25
25
25
25
25
25
25
25
25
25
25
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
1
BN
BN
BN
6
7
8
9
10
11
12
13
14
15
16
17
18
20
21
I32.3
I32.4
I32.5
I32.6
I32.7
I33.0
I33.1
I33.2
I33.3
I33.4
I33.5
I33.6
I33.7
I34.1
I34.2
Target design.
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X2
15A1-X2
15A1-X2
6F7
16S5
X5
X3
17S4
7K5X
X2
19J
TCP-20S4
X4
X3
3
2
2
13
25
25
1
13
25
1
3
25
25
16S4
16S5
14
14
16S7.1
X5
X4
X4
X3
17S4
17S5
32R6
32R7
17S8
18S2
X3
14
30
31
32
33
2
3
9
9
3
BK
40
Page/
path
15.5
15.2
15.3
15.3
6.6
16.7
17.1
17.2
17.5
18.2
19.1
19.8
21.2
21.3
21.7
21.8
21.9
16.4
16.5
16.6
16.7
16.8
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
18.2
18.3
41
43
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X2
DURMA
durmazlar
1956
P.
42
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
ESSK034E
Strip designation
16A1
16A1
16A1
16A1
16A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
19A1
32B4
TCP-25L1
TCP-25L2
TCP-25L3
TCP-25L4
TCP-25L5
TCP-25L6
HV2
X5
X5
UPPER TURRET INDEXED
UPPER TURRET FREE
LOWER TURRET INDEXED
LOWER TURRET FREE
CLAMPS POSITION CONTROL SWITCH
UPPER AUTO-INDEX GEARED
UPPER AUTO-INDEX FREE
LOWER AUTO-INDEX GEARED
LOWER AUTO-INDEX FREE
PUNCHING ROD INSIDE
FOOT PEDAL OF REF.CYL.
CW CCW TURRET TURN
=
INDEX ON INDEX OFF TURRET
MANUEL CONTROL ENABLE TURRET
15A1 PTE 2
HL BLOCK PRESSURE CONTROL SWITCH
TOOL CONTROL PHOTOCELL
CLAMP2 SHEET CONTROL
CLAMP CLUTCH FREE
=
TOOL LUBRICATION VALVE
FAULT (GENERAL)
FAULT (INDEX)
TURRETS INDEXED
TURRETS FREE
=
CW CCW TURRET TURN DIRECTION
HL BLOCK PRESSURE CONTROL VALVE
MAIN AIR VALVE
WORKCHUTE OPEN-CLOSE VALVE
22
23
24
25
26
3
4
5
6
11
12
14
15
16
17
18
20
21
22
23
25
26
1
x1
x1
x1
x1
x1
x1
x1
71
72
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
I34.3
I34.4
I34.5
I34.6
I34.7
I35.0
I35.1
I35.2
I35.3
I36.0
I36.1
I36.3
I36.4
I36.5
I36.6
I36.7
I37.1
I37.2
I37.3
I37.4
I37.6
I37.7
Q42.4
Q43.0
Q43.1
Q43.2
Q43.3
Q43.4
Q43.5
Target design.
X4
X4
X4
X4
18S8
X4
X4
X4
X4
X4
X4
TCP-20S4
TCP-20S4
TCP-20S6
TCP-20S6
TCP-20S8
21S2
21S3
X3
X3
21S8
21S9
19A1
19A1
19A1
19A1
19A1
19A1
19A1
20A1
16A1
16A1
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X2
Page/
path
41
42
43
44
NO
46
47
48
49
50
51
4
4
4
4
4
3
BK
59
60
BU
BU
35
39
40
41
42
43
44
20
44
47
18.4
18.5
18.6
18.7
18.8
19.1
19.2
19.3
19.4
20.1
20.2
20.4
20.5
20.6
20.7
20.8
21.2
21.3
21.5
21.6
21.8
21.9
32.4
25.1
25.2
25.3
25.4
25.5
25.6
27.1
27.2
27.3
42
44
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X2
DURMA
durmazlar
1956
P.
43
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
ESSK034E
Strip designation
PUNCHING ROD INSIDE VALVE
REFERENCE 1 CYLINDER VALVE(UP)
PUNCHING ROD OUTER VALVE
TURRETS INDEXED VALVE
TURRETS FREE VALVE
AUTO-INDEX GEARED VALVE
AUTO-INDEX FREE VALVE
REPOSITION CYLINDER DOWN VALVE
=
CLAMP CONTROL VALVE
CLAMP 1 RELEASE VALVE
CLAMP 2 RELEASE VALVE
=
MULTITOOL FIXED VALVE
TOOL LUBRICATION VALVE
=
=
CLAMP 4 RELEASE
=
SHEET LUBRICATION
TOOL LUBRICATION VALVE
POWER SUPPLY 220V-AC
CONTROL PANEL FAN-LUFTER
X5
X5
X5
X5
X5
X5
X5
X5
X5
X3
X3
X3
X3
X5
32A4
32A4
32Y4
X3
PV18
PV19
32A4
5L6
X0
73
74
75
76
77
78
79
80
81
82
83
84
85
86
Y1
B1
x1
90
6M3
X1
X2
6M3
N
PE
PE
PE
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
N
N
N
N
PE
PE
PE
PE
PE
PE
PE
B3
N
ELECTRIC PANEL FAN-LUFTER
CONTROL PANEL FAN-LUFTER
ELECTRIC PANEL FAN-LUFTER
OIL COOLER MOTOR
OPTIONAL SHEET REF. CONTROL SWITCH
MAIN AIR VALVE
WORKCHUTE OPEN-CLOSE VALVE
PUNCHING ROD INSIDE VALVE
Target design.
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X2
16A1
16A1
16A1
16A1
16A1
16A1
16A1
16A1
20A1
20A1
16A1
16A1
16A1
20A1
32B4
32B4
20A1
26A1
26A1
26A1
32B4
50
53
56
59
62
65
68
71
23
2
38
41
74
17
4
5
11
2
5
14
6
J
5M8
6F11
5M6
5M8
X2
21S7
2
N
4
PE
PE
PE
Page/
path
27.4
27.5
27.6
27.7
27.8
28.1
28.2
28.3
28.4
28.5
28.6
28.7
28.8
28.9
32.4
32.4
32.2
26.1
26.2
26.5
32.4
5.6
5.7
5.9
6.3
5.8
5.9
6.3
21.7
27.2
27.3
27.4
43
45
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X2
DURMA
durmazlar
1956
P.
44
49 P.
0
2
1
4
3
5
6
7
8
9
Terminal diagram
Cable name
Cable name
ESSK034E
Strip designation
Target design.
Type
Connection
Connection
Jumpers
Target design.
Terminal
number
Function text
Connection
Type
X2
Page/
path
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
REFERENCE 1 CYLINDER VALVE(UP)
PUNCHING ROD OUTER VALVE
TURRETS INDEXED VALVE
TURRETS FREE VALVE
AUTO-INDEX GEARED VALVE
AUTO-INDEX FREE VALVE
REPOSITION CYLINDER DOWN VALVE
CLAMP CLUTCH VALVE
CLAMP CONTROL VALVE
CLAMP 1 RELEASE VALVE
CLAMP 2 RELEASE VALVE
CLAMP 3 RELEASE VALVE
MULTITOOL FIXED VALVE
27.5
27.6
27.7
27.8
28.1
28.2
28.3
28.4
28.5
28.6
28.7
28.8
28.9
44
46
Name
Surname
Signature
Date
Sing
Design
KEREM KOC
Editor
KKOC
Control
LEVENT UDGU
Tested
Norm
30/12/2010
Changes
CE
Change Date
TPL93/63
671211307
X2
DURMA
durmazlar
1956
P.
45
49 P.
0
2
1
4
3
5
6
7
8
9
Bill of materials
Item designation
5A2
6A1
6A4
6A6
8A1
9A1
9A4
9A6
10A2
10A4
10A6
11A1
11A5
12A5
15A1
16A1
19A1
20A1
20A1-24R1
20A1-24R4
20A1-24R6
20A1-24R7
20A1-24R8
26A1
29A4
29A4
30A1
5F6
6F1
6F2
6F3
6F5
6F6
6F7
6F8
6F9
6F10
6F11
6F12
7K1
7K1
7K2
7K2
7K2
7K3
7K3
7K3
8K4
8K4
8K5
Amount
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Designation
Article
3UG 4511-1BP20
6EP1334-2AA01-10A
6EP1436-3BA00
6EP1334-2AA01-10A
3TK2822-1CB30
6SL3100-0BE23-6AB0
6FC5371-0AA10-0AA1
6SL3130-7TE23-6AA3
6SL3120-1TE23-0AA3
6SL3120-1TE23-0AA3
6SL3120-1TE21-8AA3
6SL3120-2TE15-0AA3
6SL3120-1TE15-0AA3
6FC 5611-0CA01-0AA0
PCU 3L-A PROFìBUS
ROLE KARTI DURMA IO-2416
I24
ROLE KARTI DURMA QB1
REL-MR- 24DC/21HC
REL-MR- 24DC/21HC
REL-MR- 24DC/21HC
REL-MR- 24DC/21HC
REL-MR- 24DC/21HC
ROLE KARTI DURMA IO-2416
6FC5210-0DF31-2AA0
6FC5203-0AF05-0AB0
6FC5303-0AF22-0AA0
5SQ2 170-2YA02-2A
5SQ2 270-2YA04-4A
5SQ2 170-2YA04-4A
5SQ2 170-2YA04-4A
5SQ2 170-2YA06-6A
5SQ2 170-2YA06-6A
UK 6.3-HESI 4A
5SQ2 270-2YA04-4A
5SQ2 170-2YA02-2A
5SQ2 170-2YA10-10A
5SQ2 270-2YA04-4A
5SQ2 170-2YA10-10A
3RT1025-1AB00
3RT1926-1CB00
3RT1025-1AB00
3RH1921-1FA31
3RT1926-1CB00
3RT1025-1AB00
3RH1921-1CA01
3RT1926-1CB00
3RH1131-1BB40
3RT1916-1BB00
3RH1131-1BB40
PHASE PROTECTION RELAY
POWER SUPPLY
POWER SUPPLY
POWER SUPPLY
SAFETY MODUL
ACTIVE INTERFACE MODULE 36KW
840DSL NCU VERSIYON 710.2
Active Line Module, 36kW
SINGLE MOTOR MODUL 30A
SINGLE MOTOR MODUL 30A
SINGLE MOTOR MODUL
DOUBLE MOTOR MODUL 2X5A
'Power module 5/10A
I/Q CARD
H+L KART PCU 3L-A RS-232
ROLE KARTI DURMA IO-2416
ROLE KARTI DURMA
ROLE KARTI DURMA QB1
ROLE 24V/16A REL-MR- 24DC/21HC
ROLE 24V/16A REL-MR- 24DC/21HC
ROLE 24V/16A REL-MR- 24DC/21HC
ROLE 24V/16A REL-MR- 24DC/21HC
ROLE 24V/16A REL-MR- 24DC/21HC
ROLE KARTI DURMA IO-2416
PCU50.3, 1.5GHz, XP
SINUMERIK OPERATOR PANELI OP 015A
MAKINE KONTROL PANELI MCP483C 1E
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
TERMINAL-FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY BLOCK
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
Supplier
Stock number
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
3301700580
3302100020
3304110284
3302100020
3301900056
3304110413
3304110374
3304110414
3304110379
3304110379
3304110378
3304140004
3304130474
3304110150
3302700200
3302700300
3302700310
3302700320
3301700845
3301700845
3301700845
3301700845
3301700845
3302700300
3304130102
3304130092
3304110082
3301800020
3301800130
3301800030
3301800030
3301800040
3301800040
3303400380
3301800130
3301800020
3301800050
3301800130
3301800050
3301000045
3301200420
3301000045
3301200055
3301200420
3301000045
3301200510
3301200420
3301100050
3301200430
3301100050
SL
SL
SL
SL
SL
SL
SIEMENS
HL VOITH
DURMA
DURMA
DURMA
KLEMSAN
KLEMSAN
KLEMSAN
KLEMSAN
KLEMSAN
DURMA
SIEMENS
SIEMENS
SIEMENS SL
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
PHÖNIX
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
45
47
Name
Design
Control
Changes
Surname
Signature
Date
KEREM KOC
Editor
LEVENT UDGU
Tested
Norm
Sing
Change Date
TPL93/63
KKOC
30/12/2010
CE
671211307
DURMA
durmazlar
1956
P.
46
49 P.
0
2
1
4
3
5
6
7
8
9
Bill of materials
Item designation
8K5
26K3
26K3
26K3
26K4
26K4
26K4
7KX
7KX
7KX
7KY1
7KY1
7KY1
7KY2
7KY2
7KY2
5M6
5M6
5M7
5M7
5M8
5M8
6M3
10M3
10M3
10M3
10M3
10M4
10M4
10M4
10M4
10M8
10M8
10M8
10M8
11M1
11M1
11M1
11M2
11M2
11M2
11M5
11M5
11M5
5Q1
5Q1
5Q1
5Q2
5Q3
5Q3
Amount
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
Designation
Article
3RT1916-1BB00
3RH1140-1BB40
3RH1911-1FA04
3RT1916-1BB00
3RH1140-1BB40
3RH1911-1FA04
3RT1916-1BB00
3RH1140-1BB40
3RH1911-1FA04
3RT1916-1BB00
3RH1140-1BB40
3RH1911-1FA04
3RT1916-1BB00
3RH1140-1BB40
3RH1911-1FA04
3RT1916-1BB00
QFF 1500
QF1 1500
QFF 3000
QF1 2500
QFF 3000
QF1 2500
AP 300/2
1FK7105-5AF71-1FGO
6FX5002-5CS51-1BA0
6FX5002-2DC10-1BA0
6SL3162-2MA00-0AA0
1FK 7105-5AF71-1FG0
6FX5002-5CS51-1BA0
6FX5002-2DC10-1BA0
6SL3162-2MA00-0AA0
1FT7086-1AF71-1MG1
6FX5002-2EQ10-1BF0
6FX5002-5CA31-1AF0
6SL3162-2MA00-0AA0
1FK7060-5AF71-1FA0
6FX5002-2DC10-1AF0
6FX5002-5CS01-1AF0
1FK7042-5AK71-1FG0
6FX5002-5CS01-1AF0
6FX5002-2DC10-1AF0
1FK7042-5AK71-1FG0
6FX5002-5CS01-1AF0
6FX5002-2DC10-1AF0
3LD 2714-0TK53
3LD9200-5C
ETK 0102
3UA59 00-2A 10-16A
GV2-ME22 20-25A
GV2-AE11
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
CONTACTOR
AUXILIARY CONTACTOR
SURGE SUPPRESSOR
COOLER MOTOR
FILTER
COOLER MOTOR
FILTER
COOLER MOTOR
FILTER
230/240v 50/60Hz 115-155Kw
SERVO MOTOR 48NM
POWER CABLE 10MT
SIGNAL CABLE 10MT
MOTOR POWER CONNECTOR
MOTOR
POWER CABLE 10MT
SIGNAL CABLE 10MT
MOTOR POWER CONNECTOR
SERVO MOTOR 27NM
ENKODER KABLOSU
MOTOR POWER CABLE 5M
MOTOR POWER CONNECTOR
SERVO MOTOR 6NM
SIGNAL CABLE 5MT
POWER CABLE 5MT
SERVO MOTOR 3NM
POWER CABLE 5MT
SIGNAL CABLE 5MT
SERVO MOTOR 3NM
POWER CABLE 5MT
SIGNAL CABLE 5MT
SWITCH
SWITCH
PANEL
OVER CURRENT RELAY
THERMIC FUSE
MOTOR PROTECTION SWITCH CONTACT
Supplier
Stock number
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
QUICK
QUICK
QUICK
QUICK
QUICK
QUICK
SESINO
SIEMENS
SIEMENS
SIEMENS
SIEMENS SL
SIEMENS
SIEMENS
SIEMENS
SIEMENS SL
SIEMENS
SIEMENS
SIEMENS
SIEMENS SL
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
SIEMENS
EMKO
SIEMENS
TELEMECANĐQUE
TELEMECANĐQUE
3301200430
3301100070
3301200085
3301200430
3301100070
3301200085
3301200430
3301100070
3301200085
3301200430
3301100070
3301200085
3301200430
3301100070
3301200085
3301200430
3302800030
3302800040
3302800035
3302800036
3302800035
3302800036
---------3300118308
3304110214
3304110215
3304130530
3300118375
3304110214
3304110215
3304130530
3300118222
3304130380
3304110208
3304130530
3300118274
3304130550
3304110216
3300118236
3304110216
3304130550
3300118236
3304110216
3304130550
3301610550
3301610515
3901001020
3301700180
3301500185
3301500400
46
48
Name
Design
Control
Changes
Surname
Signature
Date
KEREM KOC
Editor
LEVENT UDGU
Tested
Norm
Sing
Change Date
TPL93/63
KKOC
30/12/2010
CE
671211307
DURMA
durmazlar
1956
P.
47
49 P.
0
2
1
4
3
5
6
7
8
9
Bill of materials
Item designation
6Q4
7Q6
7Q6
7Q7
7Q7
7Q8
9Q1
10R3
10R5
10R8
32R6
32R6
32R7
32R7
16S4
16S4
16S4
16S5
16S5
16S5
16S7
16S7.1
17S1
17S2
18S2
18S3
18S4
18S5
18S6
18S7
18S8
19S1
19S2
19S3
19S4
19S7
19S8
20S1
20S2
21S3
21S4
21S5
21S6
21S8
21S9
6T8
TCP-25L1
TCP-25L2
TCP-25L3
TCP-25L4
Amount
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Designation
Article
3RV1011-1AA10 1.1-1.6A
GV2-ME06 1.0-1.6A
3RV1901-1E
GV2-ME06 1.0-1.6A
3RV1901-1E
GV2-ME10 4.0-6.3A
GV3-M63 40-63A
FZDP 200X35 3X1.1Ω
FZDP 200X35 3X1.1Ω
FZDP 200X35 3X2.1Ω
LZX PT 570024
LZX PT78704
LZX PT 570024
LZX PT78704
ZCP21
ZCE06
ZCPE16
ZCP21
ZCE06
ZCPE16
XCK-P2118P16
XCK-P2118P16
SME-8-K-LED-24 150855TD13
SME-8-K-LED-24 150855TD13
0830-100-629
0830-100-381
0830-100-381
0830-100-381
0830-100-381
0830-100-381
BES 516-346-H2-Y
BES M12MI-PSC40B-BV03
BES M12MI-PSC40B-BV03
BES M12MI-PSC40B-BV03
BES M12MI-PSC40B-BV03
P33K1F
PUNCH PLC CONTROL CART
BES M12MI-PSC40B-BV03
BES M12MI-PSC40B-BV03
BOS 5K-PS-IX10-01
BOS 5K-PS-IX10-01
BES 516-324-E4-C-03
BES 516-324-E4-C-03
0830-100-381
0830-100-381
400VA/400/220-24V
XVL A234
XVL A234
XVL A233
XVL A233
MOTOR PROTECTION SWITCH
THERMIC FUSE
MOTOR PROTECTION SWITCH CONTACT
THERMIC FUSE
MOTOR PROTECTION SWITCH CONTACT
THERMIC FUSE
OVER CURRENT RELAY
RESISTORS
RESISTORS
RESISTORS
RELAY
SOCKET
RELAY
SOCKET
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
LIMIT SWITCH
LIMIT SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
SWITCH
REXROTH SWITCH
REXROTH SWITCH
REXROTH SWITCH
REXROTH SWITCH
REXROTH SWITCH
SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
FOOT PEDAL
PLC CONTROL CART
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
PROXIMITY SWITCH
REXROTH SWITCH
REXROTH SWITCH
TRANSFORMER
RED LAMP
RED LAMP
GREEN LAMP
GREEN LAMP
Supplier
Stock number
SIEMENS
TEL
SIEMENS
TEL
SIEMENS
TEL
TEL
FRIZLEN
FRIZLEN
FRIZLEN
SIEMENS
SIEMENS
SIEMENS
SIEMENS
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
FESTO
FESTO
REXROTH
REXROTH
REXROTH
REXROTH
REXROTH
REXROTH
BALLUF
BALLUF
BALLUF
BALLUF
BALLUF
PRESMA
SIMICR
BALLUF
BALLUF
BALLUF
BALLUF
BALLUF
BALLUF
REXROTH
REXROTH
ETA
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
3301500010
3301500140
3301500020
3301500140
3301500020
3301500160
3301500200
3304110465
3304110465
3304110460
3301700420
3301700430
3301700420
3301700430
9170001423
9170001424
9170001425
9170001423
9170001424
9170001425
3301610135
3301610135
3304300300
3304300300
------------------------------------------------------3304300110
3304300035
3304300035
3304300035
3304300035
3302200010
3302700111
3304300035
3304300035
3304300180
3304300180
3304300120
3304300120
------------------3302000205
3300700240
3300700240
3300700230
3300700230
47
49
Name
Design
Control
Changes
Surname
Signature
Date
KEREM KOC
Editor
LEVENT UDGU
Tested
Norm
Sing
Change Date
TPL93/63
KKOC
30/12/2010
CE
671211307
DURMA
durmazlar
1956
P.
48
49 P.
0
2
1
4
3
5
6
7
8
9
Bill of materials
Item designation
TCP-25L5
TCP-25L6
TCP-8S3
TCP-20S4
TCP-20S6
TCP-20S8
Amount
1
1
1
1
1
1
Designation
Article
XVL A233
XVL A233
XB4-BS542
3SB3610-2EA11
3SB3610-2EA11
3SB 3602-2KA11
GREEN LAMP
GREEN LAMP
BUTTON
BUTTON
BUTTON
KEY
Supplier
Stock number
TELEMECANĐQUE
TELEMECANĐQUE
TELEMECANĐQUE
SIEMENS
SIEMENS
SIEMENS
3300700230
3300700230
3300700450
3300700070
3300700070
3300700060
48
Name
Design
Control
Changes
Surname
Signature
Date
KEREM KOC
Editor
LEVENT UDGU
Tested
Norm
Sing
Change Date
TPL93/63
KKOC
30/12/2010
CE
671211307
DURMA
durmazlar
1956
P.
49
49 P.
Download